FALCON II
41
Frost Protection
In cold weather the boiler may appear to run when there is no demand for heating (i.e. clocks or room
thermostats turned off). This is due to the central heating sensor going into frost protection mode. Once
the boiler has reached 14°C or more it will close down until either the temperature again falls below 7°C
or the clock or room thermostat is turned on.
For this reason we recommend that the electricity to the boiler is left turned on. If you wish to turn off the electricity
to the boiler in winter you should drain completely the heating and hot water circuits.
Cleaning
The casing requires no special cleaning, a wipe with a soft duster or damp cloth will suffice.
Maintenance
Férroli recommend that the appliance is serviced
at least once every twelve months
by a competent
engineer.
Gas Supply
It is the law that all gas appliances are installed and serviced by a competent person in accordance with
the Gas Safety Regulations (Installation & Use) 1996, and the manufacturers instructions. Failure to observe
these requirements may lead to prosecution.
Electrical Supply
WARNING - This appliance must be earthed.
The electrical wiring must be carried out by a competent electrician.
The colours of the wires in the mains lead of this appliance may not correspond with the coloured markings
identifying the terminal in the plug. Therefore, proceed as follows:
The wire coloured green and yellow must be connected to the terminal in the plug marked with either the letter
E or by the earth symbol or coloured green or green and yellow. The wire coloured blue must be connected to
the terminal marked either with the letter N or coloured black. The wire coloured brown must be connected to
the terminal marked either with the letter L or coloured red.
MINIMUM CLEARANCE
The minimum clearance around the appliance should be as follows:
Sides 5mm
Front 600mm
Below 200mm
Above 100mm
Boiler lock out
In the event of the red lockout light (
) coming on, the on/off/reset switch (A) should be turned clockwise against
the spring tension to the reset position and released (this will put the boiler into three minute delay if in the heating
mode). If the lockout light (
) illuminates repeatedly, contact an approved Férroli service engineer.