- Check the efficiency of the flue while the boiler is working.
- Check that there are no leaks from the points where the boiler/flue connects to the boiler and the
flue.
- Check that gas consumption, measured by the gas meter, matches the figure indicated in the
technical data table.
- Check that the water is circulating properly between the boiler and heating units.
- Make sure that when the pilot flame is extinguished, the safety devices are activated, shutting off
the main gas burners.
6. REGULATING
As described above, the boiler is set up to operate on natural gas (G20); gas pressure has been tested
and calibrated by the manufacturer.
However, due to possible differences in pressure in the gas supply system, at first startup you should
check and if necessary adjust the pressure at the injectors to match the pressure level shown in table
3 (paragraph 2.02) of the technical data.