47
Code 3541B140 - 11/2011 (Rev. 00)
SIS. ECOTECH 2 F
GB
1300
POSSIBLE FIXING POINTS ON FLAT ROOF
NOTES:
Each single adjustable support for flat roof must be secured against slipping or overturning due to the wind,
with at least two diam. 12 screws (to be chosen as required): directly to the roof structure, making sure to
seal the holes against water infiltration, or to a substructure prepared by the customer.
Example of substructure: concrete slabs, iron/cast iron plates, steel beams, concrete slabs with anchoring,
etc.
Attention:
The substructure, to be prepared by the customer, must be able to take the force of the wind
on the collectors and be fixed so as not to damage the roof.
The structure of the flat roof must be able to take the overall weight of the loaded supports.NOTE: In case
of installations in particular situations, a preliminary static/structural study is advisable. To make the fixing
system more stable, the number of support kits can be increased.
SIS. ECOTECH 2 F 160
SIS. ECOTECH 2 F 220
SIS. ECOTECH 2 F 280
PROFILE DIMENSIONS
1495 (mod. 160 - 280)
1795 (mod. 220)
RECOMMENDED FIXING POINTS IN
NORMAL LOAD CONDITIONS
X
RECOMMENDED FIXING POINTS IN HIGH
LOAD CONDITIONS