SUN P N
32
EN
cod. 3541F710 - Rev. 00 - 05/2017
DHW temperature adjustment
Press the Info button (detail 11 - fig. 1) until displaying the parameter
u02
of the user settings menu.
Press Enter (detail 8 - fig. 1): the actual value of the parameter
u02
is displayed.
Use the buttons (details 9 and 10 - fig. 1) to adjust the temperature from a min. of 10°C to a max. of 65°C.
Press Enter (detail 8 - fig. 1) to confirm the setting.
Then press the Info button (detail 11 - fig. 1) until exiting the menu.
Summer/Winter Switchover
Press the Info button (detail 11 - fig. 1) until displaying the parameter
u03
of the user settings menu.
Press Enter (detail 8 - fig. 1): the actual value of the parameter
u03
is displayed.
Use the buttons (details 9 and 10 - fig. 1) to set Summer mode (0) or Winter mode (1).
Press Enter (detail 8 - fig. 1) to confirm the setting.
Then press the Info button (detail 11 - fig. 1) until exiting the menu.
ECO/COMFORT selection
Heating/hot water tank temperature maintaining (Comfort) can be excluded by the user.
If excluded (Economy), domestic hot water will not be delivered.
Press the Info button (detail 11 - fig. 1) until displaying the parameter
u04
of the user settings menu.
Press Enter (detail 8 - fig. 1): the actual value of the parameter
u04
is displayed.
Use the buttons (details 9 and 10 - fig. 1) to set Economy (0) or Comfort (1) mode.
Press Enter (detail 8 - fig. 1) to confirm the setting.
Then press the Info button (detail 11 - fig. 1) to exit the menu.
Burner Max. Power
Press the Info button (detail 11 - fig. 1) until displaying the parameter
u05
of the user settings menu.
Press Enter (detail 8 - fig. 1): the actual max power step is displayed.
Use the buttons (details 9 and 10 - fig. 1) to vary the max power: from 1 (min Step) to 5 (max Step).
Table. 2 Burner max. power
Press Enter (detail 8 - fig. 1) to confirm the setting.
Then press the Info button (detail 11 - fig. 1) to exit the menu
Burner operation methodology
Press the Info button (detail 11 - fig. 1) until displaying the parameter
u06
of the user settings menu.
Press Enter (detail 8 - fig. 1): the actual value of the parameter
u06
is displayed.
Use the buttons (details 9 and 10 - fig. 1) to vary the operation methodology:
•
u06=0 (default):
Burner activation with request contact (230Vac) or with Room Thermostat contact (voltage-free).
(Remote Control request by-passed).
•
u06=1:
Burner activation from Remote Control or with request contact (230Vac).
•
u06=2:
Burner activation from Remote Control and with request contact (230Vac).
Press Enter (detail 8 - fig. 1) to confirm the setting.
Then press the Info button (detail 11 - fig. 1) to exit the menu.
Parameter value
SUN P7 N
Power - kW
SUN P12 N
Power - kW
1
14
30
2
20
36
3
25
41
4
30
48
5
34
55
Summary of Contents for SUN P N Series
Page 99: ...SUN P N 100 BG B 7 6 52 5 5 8 56 B A cod 3541F710 Rev 00 05 2017...
Page 102: ...SUN P N 103 BG cod 3541F710 Rev 00 05 2017 1 1 4 1 d2 2 6 1 4 1 d1 3 1 3 4 B sez 1 3...
Page 109: ...SUN P N 110 BG cod 3541F710 Rev 00 05 2017 1 5 B...
Page 116: ...SUN P N 117 BG cod 3541F710 Rev 00 05 2017 3 FERROLI 3 1 A 1 11 11 sez 2 4 1...
Page 118: ...SUN P N 119 BG cod 3541F710 Rev 00 05 2017 C D E 13...
Page 150: ...SUN P N 151 GR cod 3541F710 Rev 00 05 2017 1 1 4 1 d2 2 6 1 4 1 d1 3 1 3 4 B sez 1 3...
Page 157: ...SUN P N 158 GR cod 3541F710 Rev 00 05 2017 1 5 B...
Page 164: ...SUN P N 165 GR cod 3541F710 Rev 00 05 2017 3 FERROLI 3 1 pellet A 1 11 11 pellet sez 2 4 1...
Page 166: ...SUN P N 167 GR cod 3541F710 Rev 00 05 2017 12 C D E 13 A B...
Page 195: ...SUN P N 196 SR B COUNTRIES OF DESTINATION IT RO GB B A cod 3541F710 Rev 00 05 2017...
Page 198: ...SUN P N 199 SR cod 3541F710 Rev 00 05 2017 1 1 4 1 d2 2 6 1 4 1 d1 3 1 3 4 B sez 1 3...
Page 205: ...SUN P N 206 SR cod 3541F710 Rev 00 05 2017 1 5 B...
Page 212: ...SUN P N 213 SR cod 3541F710 Rev 00 05 2017 3 FERROLI 3 1 A 1 11 11 sez 2 4 1...
Page 214: ...SUN P N 215 SR cod 3541F710 Rev 00 05 2017 C D E 13...
Page 219: ......