HARDWARE
Page 11 of 12
11 MAINTENANCE AND CLEANING
The purpose of this chapter is to provide all the information on maintenance procedures and
frequency required for the
Flexible arm lamp with magnifying lens
.
INTERVENTION
Frequency
Daily
Weekly
Monthly
1. General visual inspection
X
2. Check that plates are clearly visible and
legible
X
3. General cleaning
X
4. Replacement of lamp(s)
If necessary
1.
General visual inspection:
check the overall status of the device and, in particular,
the flexible power cable and the presence of any damage or missing parts.
2.
Check the legibility of the plates:
the plates on the equipment must be perfectly
legible; it is therefore necessary to keep them clean and request a replacement if they
are illegible.
3.
General cleaning:
cleaning is necessary to free the structure, the cap and the
magnifying lens of dust or dirt.
Risks associated with cleaning
Plastic materials are used in some parts of the lamp. Applying organic solvents (such as
benzene), or other chemicals for cleaning may cause deformation or discolouration.
Clean the device gently, using a soft dry cloth.
4.
Replacing bulbs:
the bulbs must be replaced if they are burnt and/or damaged. In
this regard:
Put the switch into the "0" position and remove the plug from the power socket;
Unscrew the fixing screws on the bottom, for the closing of the cap and
protective screens, using a screwdriver and remove the screens themselves;
Disconnect the bulb from its housing;
Replace the bulb with an equivalent bulb and "close" the assembly by performing
the above steps in reverse.
fervi.com