2 USE OF THE INSTRUMENT

Using the tool is very simple. To turn on the spirit level-protractor, simply press the ON/OFF

button located on the side of the display (Ref. C Figure 2). The first time the button is

pressed the instrument is turned on, when the button is press again it will turn off the
instrument.
There is a button on the keypad used to turn on the backlight of the display (ref A) and the
HOLD button (ref B) to keep a value displayed even after the angle has been changed.

Figure 2 – Control keypad

Turning off the protractor

The goniometer is not equipped with an automatic switching-off function. So be sure to

manually turn off the instrument after use to conserve battery life.

To perform the measurement, position the body of the instrument on a measuring surface

and bring the surface plate into contact with another surface creating an angle with the first

and leading to a value being displayed. The instrument is also has a spirit level with two vials
to check the horizontal level of the surface against which the angular measurement will be

performed.

A

B

C

fervi.com

Summary of Contents for G008

Page 1: ...OPERATION AND MAINTENANCE MANUAL Digital protractor and spirit level with 2 vials Art G008 ORIGINAL INSTRUCTIONS f e r v i c o m ...

Page 2: ...ol must have all the necessary information education and receive adequate training regarding safety including a The conditions of use of the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the tool s conformity to specifications and technical instructions described in the Manual on the date of issue as listed on this page however the tool...

Page 3: ...MEASURING INSTRUMENTS Page 3 of 7 CONTENTS 1 DESCRIPTION OF THE INSTRUMENT 4 1 1 Technical specifications 5 2 USE OF THE INSTRUMENT 6 2 1 Replacing the battery 7 f e r v i c o m ...

Page 4: ...NT Figure 1 Overview of the instrument 1 Surface plate 2 Main body 3 Knob for locking unlocking the mechanism 4 Battery compartment 5 Liquid Crystal Display 6 Horizontal bubble vial 7 Vertical bubble vial 8 Push button control panel 1 2 3 4 5 6 7 8 f e r v i c o m ...

Page 5: ...MEASURING INSTRUMENTS Page 5 of 7 1 1 Technical specifications Size 415 x 50 x 20 Minimum measurable angle 0 Maximum measurable angle 225 Resolution 0 1 Accuracy 0 5 Battery 9V 6F22 f e r v i c o m ...

Page 6: ...alue displayed even after the angle has been changed Figure 2 Control keypad Turning off the protractor The goniometer is not equipped with an automatic switching off function So be sure to manually turn off the instrument after use to conserve battery life To perform the measurement position the body of the instrument on a measuring surface and bring the surface plate into contact with another su...

Page 7: ...table position Figure 3 Adjustment knob 2 1 Replacing the battery When the battery inside the instrument is uncharged it will need to be replaced The battery compartment is located at the end of the instrument Ref 4 Figure 1 To change the internal battery it is necessary to remove the cover and extract the battery from the circuit of the instrument Then insert a new battery of the same type as the...

Reviews: