3 USING THE MULTIMETER

3.1 Preliminary notes

Check that the probes are in good condition. If they are damaged, replace them.

The function selector switch must be positioned on the appropriate scale before use.

Do not perform measurements of voltage or current that exceed the maximum capacity

of the instrument.

Properly insert the battery in its compartment.

Always select a capacity which is greater than the value of current or voltage to be

measured.

Make sure the probes are properly connected to the circuit.

Remove the battery from the instrument when not in use for a long time.

Remember to turn off the instrument after use.

Do not attempt to measure the resistors inserted into live circuits or before discharging

any internal capacity of the circuit.

Select the switch depending on AC or DC.

3.2 Measurement of DC voltage DCV

1. Move the function switch to the "V" position.
2. Point the selector to the desired position If the voltage is not know, point the selector

to the highest range and reduce it to reach the appropriate range.

3. Connect the probes. The polarity of the red probe will be shown at the same time as

the voltage.

3.3 Measuring direct current DCA

1. Move the function switch to the "V" position.
2. Point the selector to the position 200mA.
3. Connect the probes. Read the value on the display.

3.4 Measuring AC voltage ACV

1. Move the function switch to the V position.
2. Point the selector to the position 200V or 500V. The reading of the measurement can

be obtained in other positions, but the decimal point is not in the exact position.

3. Open the circuit to be measured and connect the probes to the two extremes.
4. Read the value obtained on the display together with the correct polarity.

fervi.com

Summary of Contents for T051

Page 1: ...USE AND MAINTENANCE MANUAL Pocket digital multimeter Art T051 ORIGINAL INSTRUCTIONS f e r v i c o m ...

Page 2: ...instructions contained in this manual Operator Qualification The workers responsible for using this device must have all the necessary information education and receive adequate training regarding safety including a The conditions of use of the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the instrument complies with the specifications...

Page 3: ... 2 1 General Characteristics 5 2 2 Technical Specifications 5 2 2 1 Voltage DCV 5 2 2 2 Voltage ACV 6 2 2 3 Direct current DCA 6 2 2 4 Resistance 6 2 2 5 Audible continuity test and diode 6 3 USING THE MULTIMETER 7 3 1 Preliminary notes 7 3 2 Measurement of DC voltage DCV 7 3 3 Measuring direct current DCA 7 3 4 Measuring AC voltage ACV 7 3 5 Measuring resistors 8 3 6 Measuring diodes and continui...

Page 4: ... tester is designed for measurements of AC voltage VAC DC voltage VDC direct current DC resistance diodes continuity Measuring voltage Always make sure that the switch is in the appropriate position To avoid electric shock use this instrument with caution Disconnect the circuit before starting the measurement Make sure that the AC voltage or DC voltage are not connected while measuring the resista...

Page 5: ...ive polarity indication Number of measurements 2 3 times sec Low battery indication the battery symbol appears on the left side of the display Dimensions 120x70x20mm Weight 90 g including the batteries Batteries 12 V GP23A or equivalent 2 2 Technical Specifications Atmospheric conditions 0 40 C Relative humidity MAX 80 2 2 1 Voltage DCV Range Resolution Precision 18 2V 1 mV 0 8 of the reading 1D 2...

Page 6: ...e 50 to 200 KHz Maximum permitted voltage 500Vrms AC RMS indication of sinusoidal current 2 2 3 Direct current DCA Range Resolution Accuracy 200 mA 100uA 2 0 of the reading 2D Overload protection 0 5A 250V fuse 2 2 4 Resistance Range Resolution Accuracy 2 K 1 1 0 of the reading 4D 20 K 10 1 0 of the reading 4D 200 K 100 1 0 of the reading 4D 2000 K 1 K 1 0 of the reading 4D Maximum open circuit vo...

Page 7: ...ter use Do not attempt to measure the resistors inserted into live circuits or before discharging any internal capacity of the circuit Select the switch depending on AC or DC 3 2 Measurement of DC voltage DCV 1 Move the function switch to the V position 2 Point the selector to the desired position If the voltage is not know point the selector to the highest range and reduce it to reach the appropr...

Page 8: ...ion 3 If the resistance to be measured is connected to a circuit turn off the power and deactivate it before applying the probes 4 Connect the probes to the resistor read the value on the display 3 6 Measuring diodes and continuity tests 1 Move the function switch to the position 2 Move the selector to the position with the diode symbol 3 Connect the red probe to the diode anode and the black prob...

Page 9: ... Opening the instrument Make sure that the instrument is disconnected and switched off before replacing the batteries 4 1 Battery replacement 1 When the batteries are almost used the battery symbol appears on the display 2 Turn off the appliance and disconnect the probes from the circuit before replacing the battery 3 Remove the cover on the back of the unit and replace the batteries making sure t...

Page 10: ...erved of reproduction and dissemination of this Technical Manual and documentation cited and or attached It is expressly forbidden to reproduce publish or distribute any information from this Manual Copyright by FERVI 5 IDENTIFICATION PLATE f e r v i c o m ...