3.5
Address assignment of the valves
3.5.1
MPA-S valve terminal with CPX terminal
Maximum 16 MPA pneumatic modules are permitted on
the MPA-S valve terminal with CPX terminal. The following
number of solenoid coils is therefore possible
(if only valves of the same size are used):
– MPA1: up to 128 solenoid coils
(maximum of 64 valve positions)
– MPA2: up to 64 solenoid coils
(maximum of 32 valve positions)
Note
Note with the addressing that an MPA2 pneumatic module
has only 4 addresses compared to an MPA1 pneumatic
module.
Assigning the addresses
–
The assignment of the addresses is module-orientated
–
A pneumatic module always occupies
–
MPA1: 8 addresses
–
MPA2: 4 addresses
–
Counting begins on the valve terminal from left to right
–
Each valve position occupies 2 addresses, irrespective of
the valve or blanking plate fitted.
The following assignment applies:
–
solenoid coil 14 occupies the lower-value address,
–
solenoid coil 12 occupies the higher-value address.
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...