5. Maintenance and conversion
5-5
Festo P.BE-MPA-EN en 1108e
5.3
Maintenance of the MPA-S valve terminal
5.3.1
Cleaning the flat plate silencer
Caution
Fire risk due to highly inflammable cleaning materials
•
Observe the safety regulations for handling highly
inflammable cleaning materials.
Caution
Health hazard
•
Do not use chlorinated hydrocarbons (CHCs) such as
trichloroethylene (TCE), but petrol or paraffin instead.
Note
Avoiding malfunctions
Dirt in the flat plate silencer can cause an increase in
pressure in exhaust channels (3) and (5).
•
Clean the flat plate silencer if it is yellow/black or has a
dark colour, or replace it with a new insert.
You can then guarantee faultless functioning of the flat
plate silencer and avoid malfunctioning of the valves.
Proceed as follows:
1. Loosen the 6 mounting screws of the flat plate silencer
and remove it from the base components.
2. Clean the flat plate silencer with petrol or paraffin.
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...