5. Maintenance and conversion
5-17
Festo P.BE-MPA-EN en 1108e
Mounting
Proceed as follows:
Caution
Replace an electronics module only by an electronics
module of the same type.
– You can then avoid problems in controlling the solenoid
coils and damage to the electrical contacts.
Note
Before mounting, check the condition and position of the
following seals:
– The seals of the electronics module
– The ring seal of the electrical contacts
– The cord seal of the valves or blanking plates
1. Place the electronics module in the sub-base and fasten it
(tightening torque of the screws 0.4 Nm (± 20 %)).
2. Then mount the valve or blanking plates
(see section “Mounting valve or blanking plates”).