2. Fitting
2-11
Festo P.BE-MPA-EN en 1108e
Mounting
Proceed as follows:
1. Make sure that the fastening surface is flat and that it
can support the MPA-S valve terminal
(weights see Appendix A, Tab. A/1).
Make sure there is sufficient space for connecting the power
supply cables and tubing.
2. Drill mounting holes in the mounting surface.
3. Fasten the MPA-S valve terminal with M4 or M6 screws of
sufficient length to the fastening surface as per Tab. 2/3).
Dismounting
Proceed as follows:
1. Prevent a hanging-mounted MPA-S valve terminal from
falling down before you loosen it from the fastening
surface.
2. Loosen the mounting screws (see Tab. 2/3).
3. Remove the MPA-S valve terminal from the fastening
surface.
2.2.4
Additional fastening of the valve terminal
The use of additional fastening is required under the
following conditions (Tab. 2/4):
–
For MPA-S valve terminals that exceed a length of 280 mm
–
For increased vibration/shock loads (for limits for
vibration and shock, see Appendix A) Tab. A/2
–
For MPA-S valve terminals equipped with four or more
CPX interlinking blocks
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...