3. Installation
3-5
Festo P.BE-MPA-EN en 1108e
Checking the setting:
The procedure described below can be used for checking the
setting of the lubricator.
Proceed as follows:
•
Check the service units in respect of condensate and
lubricator setting twice a week.
1. Ascertain the actuator which is furthest from the
lubricator.
2. Ascertain the valve terminal which controls this cylinder.
3. Remove the silencer, if fitted, from port (3/5).
4. Hold a piece of white cardboard 10 cm in front of the
exhaust port.
5. Let the system run for a short period.
–
There must be only a slight yellow colouring on the
cardboard. If oil droplets appear, this is an indication
that too much oil has been used.
Another indicator of over-lubrication is the coloration or the
condition of the exhaust air silencer. A distinctly yellow
colouring of the filter element or drops of oil on the silencer
indicate that the lubricator setting is too high.
Summary of Contents for 530411
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 1108e ...
Page 16: ...Contents and general instructions XIV Festo P BE MPA EN en 1108e ...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 1108e Chapter 1 Summary of components ...
Page 59: ...Fitting 2 1 Festo P BE MPA EN en 1108e Chapter 2 Fitting ...
Page 73: ...Installation 3 1 Festo P BE MPA EN en 1108e Chapter 3 Installation ...
Page 108: ...3 Installation 3 36 Festo P BE MPA EN en 1108e ...
Page 109: ...Commissioning 4 1 Festo P BE MPA EN en 1108e Chapter 4 Commissioning ...
Page 172: ...5 Maintenance and conversion 5 42 Festo P BE MPA EN en 1108e ...
Page 173: ...Technical appendix A 1 Festo P BE MPA EN en 1108e Appendix A Technical appendix ...
Page 209: ...Index C 1 Festo P BE MPA EN en 1108e Appendix C Index ...
Page 210: ...C Index C 2 Festo P BE MPA EN en 1108e Contents C Index C 1 ...