DAPZ−...−AR
Festo DAPZ−...−AR 0512a English
33
Please note
The instructions on setting the switching cams in the following tables may only
be used under the following conditions:
The upper switching cam actuates the higher−order switch for the
OPEN position" of the valves (terminal strip 1 ... 3).
The lower switching cam actuates the lower−order switch for the
CLOSE position" of the valves (terminal strip 4 ... 6).
The valve closes in a clockwise direction when seen from above.
Setting the switching cam
attenuated switching / actuated switching
Valve OPEN
Valve CLOSE
1
2
3
4
5
6
1. Open the valve.
2. Insert the adjusting tool in the second
recess (see Fig.21).
3. Only if the switch is already attenu
ated/actuated
1
:
Turn the adjusting tool in an anti−clock
wise direction until the switch is no
longer attenuated/actuated
2
.
4. Turn the adjusting tool in an anti−clock
wise direction until the switching point
is reached
3
.
1. Close the valves.
2. Insert the adjusting tool in the first
recess (see Fig.21).
3. Only if the switch is already attenu
ated/actuated
4
:
Turn the adjusting tool in a clockwise
direction until the switch is no longer
attenuated/actuated
5
.
4. Turn the adjusting tool in a clockwise
direction until the switching point is
reached
6
.
Summary of Contents for 534474