2. Assembly
2-8
Festo P.BE-CDVI-EN en 1202e
Note
If you do not use the spacer bolts from Festo, note the
following:
– Make sure that there is a gap of at least 90 mm around
the CDVI, e.g. by means of mounting profiles or a section
cut out of the mounting surface, so that the tubing is not
bent.
– Make sure that there is a good conductive connec-
tion between the mounting profile and the earthed
mounting surface.
– Use the M6 mounting holes in the manifold block if you
wish to mount the CDVI on a wall (thread depth 9.5 mm).