CESA-GW-AS-PB Description
35
6.8.1
AS-I SLAVE ADR. (set/change slave address)
Main menu || SETUP ||
AS-I SLAVE ADDR
||
This function is used to change the address of a slave.
To assign a new address to a slave, the menu entry "OLD ADDRESS" and then
the slave to be changed must be selected. The new address of the slave can be
set in the menu item "NEW ADDRESS". The address change is performed by
pressing the OK button.
6.8.2
FORCE OFFLINE (Switch AS-i Master to offline operation)
Main menu || SETUP ||
FORCE OFFLINE
||
This function is used to change the address of a slave.
With "Change", this status can be changed.
Switching the AS-i master to offline operation puts the AS-i network into the safe
state. The AS-i master must be offline if an AS-i slave needs to be readdressed
via the IR-interface.
AS-I SLAVE ADDR: set/edit AS-i slave address
FORCE OFFLINE: switch AS-i master to offline operation
OPERATION MODE: operation mode
STORE ACT CFG: store current configuration
PERMANENT PARAM permanent parameters
PERMANENT CFG: permanent configuration data
ADDR.ASSISTANT: address assistant
LOS: list of offline slaves
AUTO ADDR. ENABLE: auto addressing enable
FACTORY RESET: reset to factory settings
AS-I SLAVE ADDR.
OLD ADDRESS 21A
NEU ADDRESS 03B
FORCE OFFLINE
NO
CHANGE
YES: AS-i Master is offline.
NO: AS-i Master is online.
Summary of Contents for CESA-GW-AS-PB
Page 1: ...Description AS i Gateway English Gateway AS i PROFIBUS CESA GW AS PB 749962 1002NH ...
Page 2: ......
Page 4: ......