The following tables show the possible entries for the
valve terminal in compact mode.
With input modules
Last used
string no.
No. of bytes
per input
Sum identifier
(decimal)
0
2
017
16DI
1
4
019
32DI
2
6
021
–
3
8
023
–
With output modules or valve terminals
Last used
string no.
No. of bytes
per output
Sum identifier
(decimal)
0
2
033
16DO
1
4
035
32DO
2
6
037
–
3
8
039
–
Fig. 2/5: Compact mode – possible configurations of
the inputs and outputs
Example 1
CP system with 3 strings, 3 input modules and 3 output
modules; highest occupied string number = 2.
DP identifier
Comment
0
021
6 bytes per input
1
037
6 bytes per output
Example 2
CP system with 3 strings, only 3 output modules, hig-
hest occupied string number = 2.
DP identifier
Comment
0
037
6 bytes per output
2. Commissioning
2-12
CP FB13-E 9904b