Recommendation
Providing the safety requirements of your machine/sys-
tem are fulfilled, commission the CP system with both
operating voltages (pins 1 and 2), but without com-
pressed air.
In this way, you have the possibility of testing without
the risk of unintentional reactions.
PLEASE NOTE
A CP valve location occupies two addresses.
The following applies:
– lower-value address: pilot solenoid 14
– higher-value address: pilot solenoid 12
2. Commissioning
CP FB13-E 9904b
2-31