2.3 Operation with general DP master
The Festo CP system can be controlled from any PLC,
PC or industrial PC with a PROFIBUS-DP module as
per EN 50170 (DIN 19245).
Information on the functions FREEZE and SYNC, the
DP identifiers, satndard and compact mode can be
found in section 2.1.4.
2.3.1 Starting the bus
In order to operate the CP system correctly, the DP
master must perform the following functions in the se-
quence specified:
1. Send a parametrizing telegram
2. Send a configuration telegram
3. Request diagnostic information
4. Start useful cyclic data transmission
The structure and content of the individual telegrams
are described in subsequent chapters.