background image

6. Tighten the screws at both the semi-rotary drive and process valve crosswise.

Tightening torque 

è

 Tab. 2.

7. After attaching the semi-rotary drive: check the direction of rotation of the

semi-rotary drive and position of the process valve. If the semi-rotary drive
does not run in the required direction of rotation,

è

 7.2.1 Correcting the direction of rotation of the semi-rotary drive.

7.2.1

Correcting the direction of rotation of the semi-rotary drive

DAPS-...-R-... (double-acting)

1. Remove the solenoid valve and rotate through 180°.
2. Observe position of threaded pin for orienting a NAMUR valve.
3. Mount the solenoid valve again.

DAPS-...-RS-... (single-acting)

1. Remove the screws on the drive side.
2. Rotate drive through 90° while still connected to the process valve directly or

by means of the shaft extension.

3. Tighten the screws.

7.3

Tightening torques of the retaining screws

Thread

Tightening torque [Nm]

M5

5 … 6

M6

10 … 11

M8

20 … 23

M10

45 … 50

M12

80 … 85

M14

125 … 135

M16

190 … 200

M20

370 … 390

Tab. 2 

8

Installation

8.1

Pneumatic installation

Double-acting semi-rotary drive DAPS-...-R-

Air supply at connection 4 (B): rotational movement clockwise.

Air supply at connection 2 (A): rotational movement anti-clockwise.

Single-acting semi-rotary drive DAPS-...-RS-

Air supply at connection 4 (B): rotational movement anti-clockwise

Spring return: rotational movement clockwise

Mount a filter element on the exhaust port 2 (A) to prevent ingress of dirt.

9

Commissioning

9.1

Requirements

The drive is fully mounted and connected.

9.2

Commissioning the drive

1. Pressurise drive slowly.
2. Check correct function at low travel speed.

Direction of rotation of drive

Position of process valve

9.3

Adjustment of end positions

9.3.1

DAPS-...-R-... (double-acting) – size 0015 

 1920

End position for clockwise rotation – close process valve

1 Lock nut with sealing ring

2 Threaded rod

3 Piston

4 Port 2 (A)

5 Port 4 (B)

Fig. 9 DAPS-…-R-… – close process valve

1. Supply compressed air to port 2 (A).

Ä

Process valve closes. Pistons move to the outer end position.

2. Loosen the lock nut with sealing ring.

Ä

Loosening the lock nut retains the current setting.

3. Supply compressed air to port 4 (B).

Ä

Process valve opens. Pistons move to the inner end position.

4. Adjust end position.

Rotating the threaded rod clockwise reduces the swivel angle.

Rotating the threaded rod anti-clockwise increases the swivel angle.

Depending on the product, a full revolution of the threaded rod changes the
swivel angle by approx. 1.5 … 3.5°.

5. Supply compressed air to port 2 (A).

Ä

Process valve closes. Pistons move to the outer end position against the
threaded rod.

6. Check position of the process valve.

To modify the swivel angle, repeat steps 3 and 4.

7. Tighten the lock nut with sealing ring on the threaded rod.

Tightening torque: 5 Nm

9.3.2

DAPS-...-RS... (single-acting) – size 0015 

 0960

End position for clockwise rotation – close process valve

1 Lock nut with sealing ring

2 Threaded rod

3 Spring cup

4 Piston

5 Port 2 (A)

6 Port 4 (B)

Fig. 10 DAPS-…-RS-… – close process valve

1. Exhaust the drive.

Ä

Process valve closes. Pistons move to the inner end position under spring
return, until the spring cup is held by the threaded rod or piston.

2. Loosen the lock nut with sealing ring.

Ä

Loosening the lock nut retains the current setting.

3. Supply compressed air.

Ä

Process valve opens. Pistons move to the outer end position.

4. Adjust end position.

Rotating the threaded rod clockwise increases the spring travel.

Rotating the threaded rod anti-clockwise reduces the spring travel.

Depending on the product, a full revolution of the threaded rod changes the
swivel angle by approx. 1.5 … 3.5°.

5. Exhaust the drive.

Ä

Process valve closes. Pistons move to the inner end position under spring
return, until the spring cup is held by the threaded rod or piston.

6. Check position of the process valve.

To modify the swivel angle, repeat steps 3 … 6.

7. Tighten the lock nut with sealing ring on the threaded rod.

Tightening torque: 5 Nm

End position for anti-clockwise rotation – open process valve

1 Lock nut with sealing ring

2 Threaded rod

3 Spring cup

4 Piston

5 Adjustment range for outer end

position (

è

 14 technical data)

Fig. 11 DAPS-…-RS-… – open process valve

1. Supply compressed air.

Ä

Process valve closes. Pistons move to the outer end position.

2. Loosen the lock nut with sealing ring.

Ä

Loosening the lock nut retains the current setting.

3. Exhaust the DAPS.

Ä

Process valve closes. Pistons move to the inner end position.

4. Adjust end position.

Rotating the threaded rod clockwise reduces the swivel angle.

Rotating the threaded rod anti-clockwise increases the swivel angle.

Depending on the product, a full revolution of the threaded rod changes the
swivel angle by approx. 1.5 … 3.5°.

Reviews: