2. Mounting
2−10
Festo P.BE−MPAL−EN en 1008NH
Variant
Mounting points
1
1
1
1
2
2
2
2
Valve terminal MPA−L with multi−pin plug connection
Multipin sub−base:
two M4
1
or M6 screws
2
each
Right end plate:
two M4
1
or M6 screws
2
each
1
1
2
2
1
2
Valve terminal MPA−L with CPX terminal
1
2
3
End plates:
two M4
1
or M6 screws
2
each
Pneumatic interface:
two M6 screws
3
Tab.2/2: Standard mounting points for wall mounting
Mounting
Proceed as follows:
1. Make sure that the mounting surface is flat and that it
can support the valve terminal MPA−L (weights see
appendix A, Tab.A/1).
2. Make sure there is sufficient space for connecting the
power supply cables and tubing.
3. Drill mounting holes in the mounting surface.
4. Fasten the valve terminal MPA−L with M4 or M6 screws of
sufficient length to the mounting surface (see Tab.2/2).
Summary of Contents for MPA-L Series
Page 2: ......
Page 8: ...Contents and general safety instructions VI Festo P BE MPAL EN en 1008NH ...
Page 15: ...Overview of components 1 1 Festo P BE MPAL EN en 1008NH Chapter 1 ...
Page 40: ...1 Overview of components 1 26 Festo P BE MPAL EN en 1008NH ...
Page 41: ...Mounting 2 1 Festo P BE MPAL EN en 1008NH Chapter 2 ...
Page 55: ...Installation 3 1 Festo P BE MPAL EN en 1008NH Chapter 3 ...
Page 85: ...Commissioning 4 1 Festo P BE MPAL EN en 1008NH Chapter 4 ...
Page 100: ...4 Commissioning 4 16 Festo P BE MPAL EN en 1008NH ...
Page 101: ...Conversion and maintenance 5 1 Festo P BE MPAL EN en 1008NH Chapter 5 ...
Page 128: ...5 Conversion and maintenance 5 28 Festo P BE MPAL EN en 1008NH ...
Page 129: ...Technical appendix A 1 Festo P BE MPAL EN en 1008NH Appendix A ...
Page 141: ...Supplementary overview of components B 1 Festo P BE MPAL EN en 1008NH Appendix B ...
Page 150: ...B Supplementary overview of components B 10 Festo P BE MPAL EN en 1008NH ...
Page 151: ...Index C 1 Festo P BE MPAL EN en 1008NH Appendix C ...
Page 152: ...C Index C 2 Festo P BE MPAL EN en 1008NH Contents C Index C 1 ...