MS6−SFE−...
Festo MS6−SFE−... 0507NH English
50
RECORDER mode
Enables manual accumulative consumption measurement (only when Out A is in
the [Flow] mode); select the [Flow] mode before the manual consumption measure
ment in the EDIT mode for Out A (see under EDIT mode).
1. In order to activate the EDIT mode, press the Edit button.
2. Only with active security blocking [Lock]:
S
Press the UP/DOWN button until the desired security code is set.
S
Press the Edit button
[Out A] flashes.
3. Press the UP/DOWN button until the RECORDER mode is selected
([RESET], [STOP] and [RUN] flash).
4. In order to activate the RECORDER mode, press the Edit button.
Start the measurement.
5. Select [RUN] with the UP/DOWN button (RUN flashes).
6. In order to confirm, press the Edit button
(recording starts, running light 1 segment).
A flashing RUN indicates that an accumulative consumption measurement has
been started and is active in the RECORDER mode, even if the RECORDER mode
has been exited.
Stop the measurement
7. Select [STOP] with the UP/DOWN button (STOP flashes).
8. In order to confirm, press the Edit button (recording stops).
In order to reset the measured value
9. Select [RESET] with the UP/DOWN button (RESET flashes).
10. In order to confirm, press the Edit button (measured value will be reset).
Test run
S
Carry out a test run with various flows or consumption to ascertain whether the
MS6−SFE−... switches as desired.