MS6−SFE−...
Festo MS6−SFE−... 0507NH English
55
Type MS6−SFE−...
−P2I−.../−N2I−...
−P2U−.../−N2U−...
Accuracy under rated conditions
(6bar, 23°C, horizontal mounting position)
± (3 % o.m.v. + 0.3 % F.S)
1)
Reproducibility of analogue value/
switching value
± (0.8 % o.m.v. + 0.2 % F.S)
Temperature coefficient
± 0.1 % o.m.v./K
Analogue output
[V]
[mA]
0 ... 10
4 ... 20
Load resistance
[]
ţ
10000
Ţ
500
Switching outputs
Max. output current
Residual current
Capacitive load max. DC
[mA]
[mA]
[nF]
Ţ
100
Ţ
0.05
Ţ
100
Protective functions
Protection against polarity reversal
Protection against short circuit
Protection against overloading
Inductive protective circuit
For all electrical connections
Yes
Exists
Adapted to MZ, MY, ME coils
Protection class
IP65 (as per EN 60529)
Electrical protection class
III
Cable length
[m]
< 10
1)
The air mass flow will be converted to the following standard conditions and
displayed as through flow in l/min or as consumption in l or m
3
.
Standard conditions: Temperature 0 °C, pressure 1013 mbar, atmospheric density
1.294 kg/m
3
Fig.18
Summary of Contents for MS6-SFE N2I Series
Page 30: ...MS6 SFE Festo MS6 SFE 0507NH Deutsch 30 1 1 Grundzustand RUN Modus Bild 23 SHOW Modus...
Page 32: ...MS6 SFE Festo MS6 SFE 0507NH Deutsch 32...
Page 60: ...MS6 SFE Festo MS6 SFE 0507NH English 60 1 1 Basic status RUN mode Fig 23 SHOW mode...
Page 62: ...MS6 SFE Festo MS6 SFE 0507NH English 62...