© Festo Didactic 678864
63
General
•
Trainees must only work on the station under the supervision of an instructor.
•
Observe the data in the data sheets for the individual components, in particular
all notes on safety!
Electrics
•
Electrical connections are to be wired up or disconnected only when power is
disconnected!
•
Use only low voltages of up to 24 V DC.
Pneumatics
•
Do not exceed the permissible pressure of 8 bar (800 kPa).
•
Do not switch on compressed until you have established and secured all tubing
connections.
•
Do not disconnect air lines under pressure.
•
Particular care is to be taken when switching on the compressed air. Cylinders
may advance or retract as soon as the compressed air is switched on.
Mechanics
•
Securely mount all components on the plate.
•
No manual intervention unless the machine is at rest.
2.
Notes on safety
Summary of Contents for Pick&Place Station
Page 1: ...678864 de en 04 06 R2 2 Station Pick Place Handbuch Pick Place station Manual CD ROM included ...
Page 12: ...1 Einleitung 12 Festo Didactic 678864 ...
Page 14: ...2 Sicherheitshinweise 14 Festo Didactic 678864 ...
Page 16: ...3 Technische Daten 16 Festo Didactic 678864 ...
Page 18: ...4 Transport Auspacken Lieferumfang 18 Festo Didactic 678864 ...
Page 26: ...5 Aufbau und Funktion 26 Festo Didactic 678864 ...
Page 50: ...7 Wartung 50 Festo Didactic 678864 ...
Page 54: ...Aktualisierungen 54 Festo Didactic 678864 ...
Page 62: ...1 Introduction 62 Festo Didactic 678864 ...
Page 64: ...2 Notes on safety 64 Festo Didactic 678864 ...
Page 66: ...3 Technical data 66 Festo Didactic 678864 ...
Page 68: ...4 Transport Unpacking Scope of delivery 68 Festo Didactic 678864 ...
Page 76: ...5 Design and function 76 Festo Didactic 678864 ...
Page 100: ...7 Maintenance 100 Festo Didactic 678864 ...
Page 104: ...Updates 104 Festo Didactic 678864 ...