Festo SOEL-...1606d English
29
SOEL-
No. LED pattern
Description
“ZA” status indicator
Factory setting
11
Q
1
trigger input mode:
With rising edge on Q
1
, measured value is
held until the next trigger occurs.
On = Q
1
is a trigger input
Off = Q
1
is not a trigger input
Off
12
Q
1
enable input mode:
Used to switch laser beam on and off. Laser
beam is on when Q
1
= +U
B
. If Q
1
= - U
B
, the
laser beam is switched off. Last measu-
red value remains. When reactivated, the
response time is prolonged according to the
set mean value.
On = active
Off = not active
Off
13
Switches off averaging:
The first measured value is taken into
account (page 35).
On = Averaging off
On
14
Switches on 4 ms averaging:
the first 10 meas. values are taken into
account (page 35).
On = active
Off = not active
Off
15
Switches on 40 ms averaging:
all (max. 100) meas. values are taken into
account (page 35).
On = active
Off = not active
Off
16
Set analogue output 0% (4 mA):
When S button is activated, the current
meas. value corresponds with 0% value of
the analogue output.
On* = Object within…
Off* = Object outside...
...measuring range
0% = 4 mA = end
of meas. range
17
Set analogue output 100% (20 mA): When
S button is activated, the current meas.
value corresponds with 100% value of the
analogue output.
On* = Object within…
Off* = Object outside...
...measuring range
100% = 20 mA
= start of meas.
range
18
Q
1
automatic zero mode:
For characteristic curve displacement. If Q
1
= +U
B
, the current measuring signal is set to
the analogue value 0 % = 4 mA. The incline
of the characteristic curve is maintained. If
exceeded, the characteristic curve ends at
the start or end of the measuring range.
On = Automatic zero active
Off = Autommatic zero not active
Not active
19
Q
1
automatic centre mode: displacement of
centre of characteristic curve. If Q
1
= +U
B
,
the current measuring signal is set to the
analogue value
50 % = 12 mA. The incline of the characte-
ristic curve is maintained. If exceeded, the
characteristic curve ends at the start or end
of the measuring range.
On = Automatic centre active
Off = Automatic centre not
active
Not active
* as long as the S button is pressed
Summary of Contents for SOEL-RTD-Q50-PP-S-7L
Page 2: ......
Page 4: ...4 Inhalt Content Contenu Deutsch 5 English 21 Français 37 ...
Page 20: ...Festo SOEL 1606d Deutsch 20 SOEL ...
Page 36: ...Festo SOEL 1606d English 36 SOEL ...
Page 52: ...Festo SOEL 1606d Française SOEL 52 ...
Page 53: ......