Festo SOEL-...1606d English
30
SOEL-
No. LED pattern
Description
“ZA” status indicator
Factory setting
20
Q
1
maximum hold mode:
Provided
Q
1
= +U
B
, the max. recorded measured value
is stored.
If Q
1
= -U
B
, the determined value is trans-
mitted at the analogue output. A minimum
hold can be set by inverting the analogue
characteristic curve (analogue 100% point
< analogue
0 % point).
On = Maximum hold active
Off = Maximum hold not active
Not active
21
Q
1
difference hold mode:
Provided Q
1
= +U
B
, the difference between
the measured values is saved. When Q
1
=
-U
B
, the determined value is transmitted at
the analogue output.
On = Difference hold active
Off = Difference hold not active
Not active
22
Activate factory settings:
When the S button is pressed, the factory
setting is activated.
ZA lights up as long as the S button
is pressed
Not active
23
Locking keys:
If function is activated locking becomes
active once the setting mode has been quit.
Cancel locking with RESET or the unlocking
function (see “Unlocking keys”)
On = Locking is active
Off = Locking is not active
Not active
24
Meas. value hold mode:
If no object is in the measuring range (good
target = off), the last meas. value is held at
the analogue output.
On = Meas. value hold is active
Off = Meas. value hold is
not active
Not active
Reset
When switching on the sensor (power on), keep the S button pressed (approx. 10 seconds) until the LED
lights stop flashing and are permanently on. The BA power supply indicator is green. When the S button is
released, a reset is carried out which returns the SOEL-RTD-Q50-PP-S-7L to delivery status where factory
settings are active.
(See table of functions page 28-30).
Unlocking keys
When switching on the sensor (power on), keep the T button pressed (approx. 10 seconds) until the LED
lights stop flashing and are permanently on. The ZA status indicator is red. When the T button is released,
the setting mode is unlocked.