A. Operating the SPC11 in accordance with slave profile 7.4
A-5
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
Reserved
Quit
faults
Start the
teach
procedure
Accept
the actual
position
as P.04
Accept
the actual
position
as P.03
Move to
the left
Move to
the right
Order
Description
Move to the right
All the time this bit is set, the drive will move in the direction of the
measuring system zero point.
Move to the left
All the time this bit is set, the drive will move away from the measuring
system zero point.
Accept the actual position
as P.03
When this bit is set (transition from 0 to 1) the current position will be
accepted as the intermediate position P.03.
Accept the actual position
as P.04
When this bit is set (transition from 0 to 1) the current position will be
accepted as the intermediate position P.04.
Start the teach procedure
When this bit is set (transition from 0 to 1) the teach procedure will be
started.
Quit faults
When this bit is set (transition from 0 to 1) the current fault will be
quitted.
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...