4. Commissioning
4-5
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
Button functions
The buttons on the SPC11 are only active when the AS-Inter-
face bus cable
is not supplied with power
or
not
connected.
The drive cannot be moved until the teach procedure has
successfully been completed.
Key
Description
{
/-
Reduce the input value or position value.
1)
(The drive moves in the direction of the measuring
system zero point.)
Enter/Teach
(
>
2 s)
Hold the button pressed down for at least 2 sec-
onds in order to confirm parameter values or to
start the teach procedure.
Esc (
<
1 s)
Press the button briefly in order to interrupt the
procedure.
+/
}
Increase the input value or position value.
1)
(The
drive moves away from the measuring system zero
point.)
1) Press the button briefly in order to modify the value by 1.
Hold the button pressed down in order to modify the value
continuously.
When the AS-Interface bus cable is connected and power is
applied, the buttons of the SPC11 are blocked.
If you use slave profile 7.4, you can carry out commissioning
via the AS-Interface bus. Detailed information on this can be
found in Appendix A.
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...