4. Commissioning
4-29
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
Position of the moveable mass
Switching-on behaviour
In end positions P.01...P.02
A positioning task to the appropriate end position is
generated and the moveable mass is then pressed against
that end position. The relevant output bit (O1 or O2)
supplies a 1-signal.
In taught intermediate positions
P.03...P.04
The moveable mass remains uncontrolled in the taught
positions (P.03...P.04). The relevant output bit (O3 or O4)
supplies a 0-signal. The SPC11 waits for the next position-
ing task.
Outside of positions P...
The moveable mass remains uncontrolled in the taught
position (P...). The SPC11 waits for the first positioning
task.