Festo SPC11−...−ASI 0511b English
26
6
Instructions on operation
Caution
In order to avoid damage due to uncushioned move
ment into the end positions:
Carry out commissioning again if the fixed stops have
been adjusted or if components have been replaced.
Observe the maximum permitted mass load.
Control the drive with the inputs P.01 to P.04 (see section
4). When the position is reached, a 1−signal will be dis
played at the relevant output. If a mid−position is ex
ceeded, the relevant output will supply a 1−signal for
50 ms.
Change of direction is possible at any time during
positioning.
Optimizing the positioning behaviour (if necessary).
S
Check the system structure and the compressed air
reservoir when there are fluctuations in pressure or
when the supply pressure has been modified.
S
Adapt the amplification or cushioning stage.
S
If necessary, fit restrictors in the exhaust tubing of the
MPYE−5−... in order to reduce speed.
Control, parametrizing and diagnosis via the AS−Interface
bus is possible with slave profile 7.4.