background image

4

Festo — VABA-S6-1-AP — 2022-06

Additional information

1

Applicable documents

All available documents for the product 

è

  www.festo.com/sp.

Document

Product

Table of contents

Assembly instructions

Valve terminal VTSA, VTSA-F

Manual

Valve terminal VTSA, VTSA-F

Pneumatics description

Operating instructions

Automation system CPX-AP-I

Tab. 1: Applicable documents

2

Safety

2.1

Safety instructions

Before working on the product, switch off the power supply and secure it against being switched on
again.

Before working on the product, switch off the compressed air supply and lock it to prevent it from
being switched on again.

Exhaust system parts with stored compressed air.

Only use the product if it is in perfect technical condition.

Only use the product in its original condition without unauthorised modifications.

Only the conversions or modifications described in the documentation are permitted. Conversions
can change the function of the valve terminal. Check the conversion target with the configurator
before carrying out conversions 

è

  www.festo.com.

Take into account the ambient conditions at the location of use.

Observe the handling specifications for electrostatically sensitive devices.

The product may generate high frequency interference, which may require interference suppression
measures in residential areas.

Store the product in a cool, dry environment protected from UV and corrosion. Keep storage times
short.

2.2

Intended use

The electrical interface connects a valve terminal VTSA-MP(-NPT) or VTSA-F-MP(-NPT) to an automa-
tion system CPX-AP-I.

2.3

Training of qualified personnel

Work on the product may only be carried out by qualified personnel who can evaluate the work
and detect dangers. The qualified personnel have skills and experience in dealing with electrical
(open-loop) control technology.

3

Additional information

Contact the regional Festo contact if you have technical problems 

è

  www.festo.com.

Accessories and spare parts 

è

  www.festo.com/catalogue.

Summary of Contents for VABA-S6-1-AP

Page 1: ...VABA S6 1 AP Electrical interface Operating instruc tions 8177299 2022 06 8177301 ...

Page 2: ...Translation of the original instructions ...

Page 3: ... 4 Product overview 5 4 1 Product design 5 4 2 Function 5 5 Mounting 5 6 Installation electrical 6 6 1 Interfaces 6 6 2 Earthing 7 7 Commissioning 7 8 Operation 8 8 1 Address assignment 8 8 2 Parameterisation 8 9 Malfunctions 9 9 1 Diagnostic messages 9 9 2 LED displays 11 10 Technical data 12 10 1 Technical data general 12 10 2 Technical data mechanical 13 10 3 Technical data electrical 13 ...

Page 4: ...ermitted Conversions can change the function of the valve terminal Check the conversion target with the configurator before carrying out conversions è www festo com Take into account the ambient conditions at the location of use Observe the handling specifications for electrostatically sensitive devices The product may generate high frequency interference which may require interference suppression...

Page 5: ...roduct is also suitable for retrofit in existing valve terminals with multi pin connection type VTSA MP NPT and VTSA F MP NPT The product can be fitted with the inscription label ASLR C E4 When retrofitting the VABA S6 1 AP in existing valve terminals note the following The installation changes the function of the valve terminal Before installing the new configuration check its validity online wit...

Page 6: ...1 Carry out electrical installation è 1 Applicable documents Operating instructions automation system CPX AP I 6 1 Interfaces Connection for power supply XD1 M8 plug 4 pin A coded Signal 1 24 V DC logic supply PS 2 0 V DC load supply PL 3 0 V DC logic supply PS 4 24 V DC load supply PL Tab 2 Connection for power supply Observe the information on the power supply see the operating instructions for ...

Page 7: ...on for system communication forwarding 6 2 Earthing Connect the valve terminal to the functional earth via the earth terminal è 4 1 Product design 7 Commissioning Commission the automation system è 1 Applicable documents Operating instructions automa tion system CPX AP I Response of the display components of the module after error free commissioning MD PL green light green light Tab 6 Response of ...

Page 8: ...e following allocation applies here Solenoid coil for switching position 14 lower value address Solenoid coil for switching position 12 higher value address 1 2 4 3 Fig 2 Example of address assignment with 12 valve positions 1 Example of valve position 0 Solenoid coil SP1 address 0 Solenoid coil SP2 address 1 2 Blanking plate 3 Addresses of the solenoid coils 14 4 Addresses of the solenoid coils 1...

Page 9: ...ID Parameter Instances Data type Access1 Arraysize 246 Fieldbus serial number 1 UINT32 ro 791 Product Key 1 CHAR ro 12 960 Firmware version 1 CHAR ro 30 20000 Module code 1 UINT32 ro 20085 Measured value of temperature AP ASIC C 1 INT16 ro 20087 Current measured value of logic supply PS mV 1 UINT16 ro 20088 Current measured value of load supply PL mV 1 UINT16 ro 20093 Hardware version 1 UINT8 ro 1...

Page 10: ... 0105 33620229 Undervoltage in load supply PL 24 V DC Undervoltage in the load supply PL 24 V DC was detected Remedy Check power supply load Check for short circuit Diagnos tics status Error 02 01 0106 33620230 Switch off load supply PL 24 V DC A shutdown of the load voltage supply PL was detected The cause can be a deliberate shutdown by the emergency stop Remedy Check whether emergency stop was ...

Page 11: ...off load supply PL flashing red Module diagnostics active Degree of severity Warning e g parameterisation error Take appropriate remedial action e g check parameterisation red light Module diagnostics active Degree of severity Error e g undervoltage in load supply PL Take appropriate remedial action e g check load supply PL fast red flashing Module ramp up not yet completed System communication no...

Page 12: ... data general VABA S6 1 AP Ambient temperature C 5 50 Storage temperature C 20 60 Humidity 5 95 non condensing Degree of protection IP651 Mounting position è 1 Applicable documents Manual valve terminal VTSA VTSA F Storage time years Max 2 Number of solenoid coils Max 24 Assigned address space inputs outputs Byte 3 Module code hex dec 0x2022 8226d Module identification VABA S6 1 AP Electromagnetic...

Page 13: ...y PL V DC 24 _ 10 Intrinsic current consumption of the module at nominal operating voltage 24 V from PS mA 34 from PL mA 15 Diagnostic messages Undervoltage Overvoltage Logic supply PS V 18 30 Load supply PL V 21 6 26 4 Capacitive load at load supply PL 24 V PL to 0 V PL nF Typically 35 24 V PL to FE nF Typically 35 0 V PL to FE nF Typically 20 Electrical isolation Between PS and PL Yes Between th...

Page 14: ... 2022 all rights reserved to Festo SE Co KG Copyright Festo SE Co KG 73734 Esslingen Ruiter Straße 82 Deutschland Phone 49 711 347 0 Internet www festo com ...

Reviews: