Festo — VTSA-F-CB — 2021-06a
Technical data
105
Electrical
Width
18 mm
26 mm
42 mm
52 mm
Intrinsic current consumption VABA-S6-1-...-CB at 24 V
Electronics only
[mA]
Typically 20 (from U
EL / SEN
)
Valves
[mA]
Typically 24 (from U
VAL
)
Intrinsic current consumption VABA-S6-1-...-F1-CB and VABA-S6-1-...-F2-CB at 24 V DC
Electronics without CPX-FVDA-P2
[mA]
Typically 11 (from U
EL / SEN
)
Electronics with CPX-FVDA-P2
[mA]
Typically 20 (from U
EL / SEN
)
Valves without CPX-FVDA-P2
[mA]
Typically 6 (from U
VAL
)
Valves with CPX-FVDA-P2
[mA]
Typically 22 (from U
VAL
)
Intrinsic current consumption VABA-S6-1-X2-...-CB2-AL at 24 V DC
Electronics without CPX-FVDA-P2
[mA]
Typically 4 (from U
EL / SEN
)
Electronics with CPX-FVDA-P2
[mA]
Typically 6 (from U
EL / SEN
)
Protection against electric shock
Protection against direct and indirect
contact in accordance with EN 60204-1
By PELV circuit (protected extra-low voltage)
Electromagnetic compatibility
EMC emitted interference
è
Declaration of conformity
EMC interference resistance
Tab. 77: Technical data, electrical
Voltage supply for the vacuum generator VABF
Fig. 65: Minimum voltage supply U
EL / SEN
as a function of ambient temperature