SYS‑PST 1500 Li HP is only suitable for
use indoors or in an equivalent, dry
working environment.
The user is liable for improper
or non-intended use.
4
Technical data
Battery
Continuous power
3680 W
Peak power (0.5 sec.)
11,000 W
Peak power (6 sec.)
7200 W
Nominal energy content
18 x 86.4 Wh
Charging duration
Approx. 3 hours at
230 V
If the battery is fully charged, it remains operational
when switched off:
> 2 years
Connections
AC output
EU (without
DK)
230 V
50 Hz
16 A
DK
230 V
50 Hz
16 A
CH
230 V
50 Hz
16 A
GB
230 V
50 Hz
13 A
AC charging input
120–240 V
50–60 Hz
4 A
DC output compatible with
USB‑C
TM
5–20 V
3 A
General
Required charging power
≥ 900 W
Operating temperature
-20 °C to 65 °C
Charging temperature
0 °C to 45 °C
IP protection class (with protective covers closed)
IP44
Systainer
3
dimensions SYS3 M 187 (W x H x D)
396 x 296 x 187 mm
Weight
16.3 kg
English