background image

LEX 3

17

GB

6

Compressed-air supply and 

commissioning

6.1

Compressed air preparation

The machine is designed for lubricated and

non-lubricated operation.
The Festool service unit VE must be used in

lubricated operation. Consisting of a filter,

control unit, condensation drain and lubrica-

tor, the service unit cleans and lubricates the

compressed air and keeps it free of conden-

sation. Here, the lubricator should be set so

that a drop is applied to the compressed air

approx. every 15 minutes.

Damage that occurs as a result of in-

correct compressed air processing is

excluded from warranty claims.

We recommend a service unit with a 3/8"

connector, when up to two Festool com-

pressed air tools are used.
A compressor that supplies at least 350 l/min

at an operating pressure of 6 bar should be

used to supply compressed air.
The diameter of the piping system must be

sufficiently large (at least 9 mm).

6.2

Connection for IAS hose system 

[3]

The IAS hose system combines several func-

tions in one hose depending on the version:
– Compressed air supply 

[3-1]

– Exhaust air extraction 

[3-2]

– Dust extraction 

[3-3]

6.3

Switch on/off

Switching-on: Press 

[1-1]

 switch.

Switching off: Release 

[1-1]

 switch.

7

Settings

7.1

Setting and adjusting the speed

Can be adjusted at the control lever 

[1-4]

between 

This enables you to optimise the material re-

moval capacity to suit the respective materi-

al or application.

7.2

Replacing the sanding pad [4]

An optimal work result can only be

achieved using original accessories and

consumables. The use of non-original

accessories or consumables invalidates the

right to claim under warranty.

Health risk:

 Fitting sanding pads of in-

correct size causes excessive vibration

of the machine.

Tuned to the surface being processed, the

machine can be equipped with three sanding

pads of different hardnesses.

Hard:

 Coarse and fine sanding on surfaces.

Sanding edges.

Soft:

 Universal for coarse and fine sanding,

for flat and convex surfaces.

Extra-soft:

 Fine sanding of moulded parts,

arches, radii. Do not use on edges.

7.3

Attaching sanding accessories 

using StickFix [4b]

The suitable StickFix sandpaper and StickFix

sanding cloth can be attached quickly and

simply to the StickFix sanding pad. 

X

Press the self-adhesive sanding accessory

onto the sanding pad 

[1-5]

.

7.4

Dust extraction

L

For use of a Festool mobile dust extractor

with flow sensor

: Adjust hose diameter

of mobile dust extractor to Ø 27 mm.

To guarantee optimal dust extraction, we

recommend using Festool extractors with au-

tomatic switch-on/switch-off device for com-

pressed air machines.

CAUTION

Risk of injury 

X

Make sure that the pneumatic tool is

switched off when you connect the com-

pressed-air supply. 

CAUTION

Risk of injury

X

The machine should always be disconnect-

ed from the compressed air supply before

any work is carried out on the machine.

LEX 3 77/2.5

7.800 - 10.500 rpm

LEX 3 125/3, 125/5

7.500 - 9.500 rpm

LEX 3 150/3, 150/5

7.000 - 10.000 rpm

WARNING

Dust hazard

X

Always work with a dust extractor.

X

Always observe country-specific regulations.

Summary of Contents for 5

Page 1: ...zing Lijst met reserveonderdelen 40 Originalbruksanvisning Reservdelslista 47 Alkuperäiset käyttöohjeet Varaosaluettelo 53 Original brugsanvisning Reservedelsliste 60 Originalbruksanvisning Reservedelsliste 66 Manual de instruções original Lista de peças sobresselentes 72 Оригинал Руководства по эксплуатации Перечень запасных частей 79 Originál návodu k obsluze Seznam náhradních dílů 87 Oryginalna...

Page 2: ...Click 1 1 1 2 1 3 1 4 1 5 1 2 LEX 3 150 ...

Page 3: ...3 1 3 2 3 3 3 1 3 2 3 3 3 1 3 2 IAS 3 IAS 2 IAS 3 light IAS 3 SD 3 ...

Page 4: ...5 2 5 1 4 4b 5 StickFix ...

Page 5: ...r replacing accessory parts you must have read and understood all safety instructions and information Ig Warning of general danger Risk of electric shock Read the Operating Instructions Notes Wear ear protection Wear protective goggles Wear a dust mask Do not throw in the household waste Oil free compressed air 1 1 On Off switch 1 2 Button for loosening the IAS connec tion 1 3 IAS connection adapt...

Page 6: ...e developed for this purpose Wear protective goggles protective gloves and protective clothing Check sanding pad before each use Do not use the sanding pad if it is torn broken or has fallen Avoid direct contact with the sanding pad Wear suitable gloves as protection Never use without an abrasive Risk of an electrostatic discharge if the com pressed air tool is used on plastic and other non conduc...

Page 7: ...ted e g the use of insulating materials Wear ear protection Observe instructions from the employer or occupational and health regulations Operate and maintain compressed air tool according to these operating instructions Select maintain and replace accessories and consumables according to these operating in structions Assure function of the silencer at the com pressed air tool Vibration hazard Vib...

Page 8: ...ir tool repaired by a qualified specialist This compressed air tool corresponds to the relevant safety regula tions Repairs should only be carried out by a qualified specialist The operator is otherwise at risk of an accident Only work with correctly processed compressed air Using the Festool supply unit VE guarantees this 5 2 Other risks In spite of compliance with all relevant design regulations...

Page 9: ...ng pad 4 An optimal work result can only be achieved using original accessories and consumables The use of non original accessories or consumables invalidates the right to claim under warranty Health risk Fitting sanding pads of in correct size causes excessive vibration of the machine Tuned to the surface being processed the machine can be equipped with three sanding pads of different hardnesses ...

Page 10: ...eek particularly if sanding synthetic resin in the case of wet sanding and if sanding plaster 5 2 using a small flat brush or a cloth 10 Accessories The order numbers of the accessories and tools can be found in the Festool catalogue or on the Internet under www festool com 11 Environment Do not dispose of the device in household waste Recycle de vices accessories and packaging Observe applicable ...

Reviews: