12
CTL MINI/MIDI
GB
6.1
Connecting the mobile dust extractor
The switch
[1-11]
serves as an on/off switch.
Switch position "0"
Appliance socket
[1-2]
is disconnected from the
power, mobile dust extractor is switched off.
"MAN" switch position
Appliance socket
[1-2]
is connected to the power, the
mobile dust extractor starts.
"Auto" switch position
Appliance socket
[1-2]
is connected to the power, the
mobile dust extractor starts when the connected tool
is switched on.
Insert the plug into an earthed socket.
Pull the plug from the socket when the ma-
chine is not in use and prior to maintenance
and cleaning work.
6.2
Connecting electric power tools
Connect the electric power tool to the appliance
socket
[1-2]
.
6.3
Connecting the suction hose [1A]
Connect the suction hose to the angle adapter
[1-
6]
on the extraction opening
[1-5]
.
7
Settings
7.1
Adjusting the suction power
Use the rotary knob
[1-1]
.
7.2
Applying the brake [1B]
Raise the front of the dust extractor slightly.
Push down the brake
[1-13]
until it engages into
position.
Actuate the lever
[1-12]
to release.
7.3
Temperature cut-out
A temperature cut-out switches the mobile dust ex-
tractor off when it reaches a critical temperature to
prevent overheating.
Switch off the mobile dust extractor, allow to cool
for about 5 minutes then switch on again.
Not possible to switch on: contact Festool service
workshop.
7.4
SYSDOC
A Systainer can be secured to the storage area
[1-7]
using the T-LOC latch
[1-8]
. Systainers without a T-
LOC can be secured using four SysDoc latches
[1-3]
.
8
Working
8.1
Extracting dry materials
When extracting dust that exceeds the permit-
ted limit values, only extract from a single ma-
chine (electric or air tool).
Observe
the following when extracting dust generat-
ed by operating electric power tools:
Ensure there is adequate ventilation! Observe re-
gional regulations!
Limit values:
exhaust air max. 50% of the clear air
volume
Formula:
room volume V
R
x air renewal rate L
W
8.2
Extracting wet materials/liquids
Remove the filter bag!
Recommendation:
use a special wet filter.
The dust extractor stops automatically when the
maximum level is reached.
After wet extraction, allow the main filter to dry!
8.3
After finishing work
Switch off the mobile dust extractor and pull out
the mains plug.
Wind up the mains power cable.
Empty the dirt trap.
Place the suction hose
[2-1]
and mains power ca-
ble
[2-2]
in the top section. Insert the mains cable
through the recess
[2-3]
.
Vacuum and wipe off the inside and outside of the
WARNING
Risk of injury from tools starting up unexpectedly
Before setting the switch to the "AUTO" or
"MAN" position, make sure that the connected
tool is switched off.
WARNING
Risk of injury
Observe the maximum appliance socket con-
nected load (see chapter "Technical data")
Switch off the electric power tool.
CAUTION
Hazardous dust
Damage to the respiratory passage
Always use a filter bag!
CAUTION
Escaping foam and fluids
Switch off and empty the machine immediately.