Fault clearance
Malfunction
Possible cause
Remedy
MS6-SV-D
does not
switch.
Insufficient power.
Provide sufficient power.
Pressure supply interrupted.
Restore compressed air supply.
Malfunction due to electrical or electro
magnetic effects (EMC measures not
complied with).
Note the maximum length of the
signal lines.
Run the control and power lines
separately.
Use screened lines.
Provide low-impedance paths to
earth.
Pressure p1
collapses
briefly at every
switching op
eration.
The cross-section of the MS6-SV-D pres
sure supply is too small.
Tighten flow control screw a little.
Attach reservoir in front of inlet p1.
Modify the compressed air supply
(e.g. increase cross-section of the
supply hose).
Tab. 11
Fault clearance
Perform the following steps if a malfunction occurs:
Check compressed air supply.
Check power supply.
Check installation of the signal lines.
Commission device (
è
8 Commissioning).
Implement possible remedies (
è
Tab. 11).
If the malfunction occurs again:
Contact Festo repair service.