Note
Failure of the safety function
Common cause failures, subsequently called CCF, cause the failure of the safety func
tion, since in this case both channels in a two-channel system fail simultaneously.
If measures to control the CCFs are not observed, the safety function of the soft-start/
quick exhaust valve can be impaired.
Make sure that the described measures for managing the CCFs are observed
(
è
3.2 Common cause failures (CCF) and 15.1 Safety characteristics).
Note
Failure of the safety function
Failure to observe the technical data can result in the failure of the safety function.
Observe the technical data (
è
15 Technical data).