background image

Menu Features: Batch Parameters 

 

PROGRAM

 

Programming Items 

Factory set  Default

Programming Range

 

Notes

 

Batch 1 LEFT*

 

  Batch Summary  

Display Summary 

 

 

 

  Batch Name  

Regular 1(-16) 

Choose from list: 

Regular1

 

(Regular 1-16) 

-OR- Write: any name 

CBS-2151& 2152XTS

 

1 ½ Gallon 

  Batch Volume  

1.50 gal 
 [ 0.50-2.00] 

1.5 gal 

|_________

[]

________| 

0.50                           2.00 

 

CBS-2152XTS

 

2 Gallon

 

  Batch Volume  

2.00 gal 
 [ 0.50-2.25] 

2.5 gal 

|_____________

[]

____| 

0.50                           2.25 

 

 

  Brew Time  

4:00 mm:ss 
[ 2:00-10.00] 

4:00 mm:ss 

|_____

[]

___________| 

2:00                          10:00 

 

 

  Nr Of Pulses  

|_____

[]

___________| 

1                                 30 

 

 

  Prewet Perc.  

0% 

0 % 

|_

[]

_______________| 

0                               15 

 

 

  Bypass Perc.  

0% 

0 % 

|_

[]

_______________| 

0                               40 

 

 

  Drip Delay  

1:30 mm:ss 

1:30 mm:ss 

|_____

[]

___________| 

0:30                          5:00 

 

Batch 2 Left**

 

**Batch 2-4—Right and Batch2-4—Left may be individually selected-or-entirely deleted 

 

  Batch ON/OFF 

ON 

ON 

|_________

[]

________| 

ON                           OFF 

 

 

  Batch Summary  

Display Summary 

 

 

 

  Batch Name  

Regular 1 

Regular 1-16;Write own name 

 

CBS-2151& 2152XTS

 

1 ½ Gallon 

  Batch Volume  

1.50 gal 
 [ 0.50-2.00] 

1.5 gal 

|_________

[]

________| 

0.50                           2.00 

 

CBS-2152XTS

 

2 Gallon

 

  Batch Volume  

2.00 gal 
 [ 0.50-2.25] 

2.5 gal 

|_____________

[]

____| 

0.50                           2.25 

 

 

  Brew Time  

4:00 mm:ss 
[ 2:00-10.00] 

4:00 mm:ss 

|_____

[]

___________| 

2:00                          10:00 

 

 

  Nr Of Pulses  

|_____

[]

___________| 

1                                 30 

 

 

  Prewet Perc.  

0% 

0 % 

|_

[]

_______________| 

0                               15 

 

 

  Bypass Perc. 

0% 

0 % 

|_

[]

_______________| 

0                               40 

 

 

  Drip Delay  

1:30 mm:ss 

1:30 mm:ss 

|_____

[]

_________| 

0:

30                          5:00

 

 

Batch 3 Left

 ** 

(See Batch 

2-Left

 

 

 

Batch 4 Left

 ** 

(See Batch 

2-Left

 

 

 

Batch 1 Right

 * 

(See Batch 

1-Left

 

 

 

Batch 2 Right

 ** 

(See Batch 

2-Left

 

 

 

Batch 3 Right

 ** 

(See Batch 

2-Left

 

 

 

Batch 4 Right

 ** 

(See Batch 

2-Left

 

 

 

Batch Copy

  

Copy From Batch 

L1 

L1-L4;R1-R4 

 

 

Copy To Batch 

L1 

L1-L4;R1-R4 

 

 Copy? 

L1

Æ

L2?  

(example) 

NO 

|_______________

[]

__| 

YES                         NO

 

 

*

Batch 1&4 cannot be disabled. (

CBS-2152XTS

);  

*

Batch 1 cannot be disabled. (

CBS-2151XTS

)  

**

Batch can be disabled, and removed from display 

 
 
 
 

Summary of Contents for CBS-2150XTS Series

Page 1: ...ng operator access programming 6 Menu Features Batch Parameters 7 How to calibrate the flow rate 11 Operator Training 14 Safety Notes 13 Error Codes 13 Service Guide to a Successful Installation 15 In...

Page 2: ...NLY 2 gallon 7 6 liters per brew Coffee Filters 15 X 5 Brew Time all models Factory set at 5 5 minutes 4 minute brew time 1 5 minute drip delay Temperature Control Water temperature is factory set at...

Page 3: ...FF Touch screen will briefly illuminate Turn main power switch to ON Switch located lower right side of back panel When Complete the HOME SCREEN will display Immediately touch and hold finger to enter...

Page 4: ...penser under brewbasket Use the convenient locator guide Tap READY screen to enter the batch selection menu A long duration TAP with fingertip Touch a top batch key for REGULAR 1 Touch batch pennant w...

Page 5: ...2152XTS brewing simaltanously Left side completing drip delay Brew basket sensor enabled Unit is brewable only when brebasket is in place option may be disabled by user CBS 2152XTS dual side right si...

Page 6: ...gramming items shown below Programming category screens Menu Tree Programming category screens To enter Turn unit OFF After 10 second delay turn unit ON Home Screen will appear Immediately place finge...

Page 7: ...N ON _________ ________ ON OFF Batch Summary Display Summary Batch Name Regular 1 Regular 1 16 Write own name CBS 2151 2152XTS 1 Gallon Batch Volume 1 50 gal 0 50 2 00 1 5 gal _________ ________ 0 50...

Page 8: ...s for reverse osmosis water or very pure water Most water has sufficent mineral content for proper brewer refill cycling If refill is erratic inspect all wiring and if ERROR CODE 107 displays or if wa...

Page 9: ...___________ ____ YES NO If Yes Follow directions on the touch screen INPUT SUMMARY SCREEN Display Inputs See INPUTS Service Screen Brew Basket Sensor High Liquid Level Probe Low Liquid Level Probe Tan...

Page 10: ...test TEST Press To Test Runs Valve to verify flow Have container under brewbasket R Valve Calib Calibrate Flow Rate 3400 ml p m _________ ________ 3000 3800 Factory or service use for flow rate R Byp...

Page 11: ...CALIBRATE THE FLOW RATE Enter this number in milliliters into the calibration slider for the Valve tested in the OUTPUT MENU Use milliliters If measured in fluid ounces fl oz multiply by 29 57 to con...

Page 12: ...Model CBS 2131 2152 Series ________________ ____ Scroll to your brewer and tap ENTER tab Total Counters Counters Display Counters OR Display Resettable Counters Counters Display Total Counters Left B...

Page 13: ...ure probe Bad probe connection or probe failure Check all connections Replace probe if necessary 100 Initial Fill Error Initial fill time was more than 4 minutes after power up Water supply flow rate...

Page 14: ...brew basket 2 Never strike a brewbasket or hit it against a hard surface This will damage the brew cone and may damage the brewbasket support rails 3 Rinse dispensers before reuse Every Day 1 Wash bre...

Page 15: ...and waste piping and connections shall comply with the International Plumbing Code 2003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all...

Page 16: ...for the unit and verify that it will fit properly in the space intended for it Verify that the counter or table will support the total weight of the brewer and dispensers when filled See Technical Dat...

Page 17: ...nt or if the unit must be hard wired 4 Access the terminal block for electrical connection by removing the pullout service module on the lower back 5 A fused disconnect switch or circuit breaker on th...

Page 18: ...9mm CBS 2152XTS Dual 1 gallon 36 933mm 21 552mm 20 518mm 77lb 35kg 174lb 78 7kg 220lb 99 8kg 11 5 gal 43 7 l 90lb 41kg 22 x 27 x 35 559x686x889mm CBS 2152XTS Dual 2 gallon 38 986mm 21 552mm 20 518mm 8...

Page 19: ...America International Versions CBS_2151XTS Single 1 gallon version Electrical Configurations Configuration Code Plastic Brewbasket Stainless Steel Brewbasket Heater Configuration Voltage Phase Wires E...

Page 20: ...6 10 1 36 9 42 5 25 3 gal 97 liters E215295 E215295M 3 X 5 0 kW 208 240 3 4 G Hardwired 11 4 15 1 32 0 36 9 38 3 gal 145 liters Has UL cUL and NSF 4 certification Not certified CE International Not C...

Page 21: ...d as 1 phase 3 X 3 0 kW 208 240 3 3 G Hardwired 6 9 9 1 19 5 22 5 22 5 gal 85 liters E215352 E215352M 2 X 5 0 kW 208 240 1 2 G Hardwired 7 6 10 1 36 9 42 5 25 3 gal 97 liters Selectable sold as1 phase...

Page 22: ...will be displayed 8 After the water has reached the set temperature Screen 3 will display READY 9 Review the Operating Instructions Brew one full batch water only on each side to confirm proper fill...

Page 23: ...BB HANDLE 1023 00190 00 RED PLUG BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE Brown colored insert is standard Brewbasket handle plug for polymeric brewbaskets is...

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ...34 CBS 2152XTS 52...

Page 35: ...TANK ASSY 2 X 3 0kW 240VAC CBS 2152 XTS 28 1 1104 00081 00 TANK ASSY 2 X 5 0kW 240VAC CBS 2152 XTS 28 1 1104 00062 00 TANK ASSY 3 X 3 0kW 240VAC CBS 2152 XTS 28 1 1104 00075 00 TANK ASSY 3 X 4 0kW 24...

Page 36: ...36 Drawing 1101 00214 00 CBS 2151XTS...

Page 37: ...3 00007 00 LEG FLANGE FOOT 4 HIGH 28 1 1023 00159 00 CORNER INSERT 29 2 1024 00049 00 EDGE PROTECTOR 7 00 LG CBS 2130 30 1 1102 00210 00 ASSEMBLY FRONT PANEL CBS 2130 GRAVITY VERSION 31 4 1082 00058 0...

Page 38: ...VER 12 1 1102 00007 00 TANK COVER ASSEMBLY 13 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 13 1107 00010 00 HEATER ASSEMBLY IMMERSION 4000W 240VAC 13 1107 00032 00 HEATER ASSEMBLY IMMERSION 50...

Page 39: ...N 3000W 240VAC 12 1 3 1107 00010 00 HEATER ASSEMBLY IMMERSION 4000W 240VAC 12 1 3 1107 00032 00 HEATER ASSEMBLY IMMERSION 5000W 240VAC 12 1 3 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 13 1...

Page 40: ...TOOTH LOCK 5 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 6 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 7 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC 8 3 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW...

Page 41: ...6 00031 00 BUSHING STRAIN RELIEF BLACK 354 630 8 4 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 9 4 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 10 1 1112 00246 00 WELDMENT BRACKET TERMINAL...

Page 42: ...8 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC 6 3 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 7 1 1044 00003 00 LABEL GROUND 8 1 1003 00170 00 BRACKET GUARD 9 4 1081 00006 00 SPACER 6MM OD x 3 2MM I...

Page 43: ...WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 8 4 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 9 1 1046 00030 00 LABEL WARNING DISCONNECT FROM POWER SOURCE 10 1 1112 00268 00 WELDMENT BRACKET TERMINAL BLOC...

Page 44: ...44...

Page 45: ...45...

Reviews: