3. Mechanical Installation

3.1 Introduction

The following tools will be needed:

• 3mm hexagon key for lid screws

• 4mm hexagon key to adjust SET LEVEL

• Wire strippers and wire cutters

• 3mm flat blade torque screwdriver for terminal block electrical connections

• 5mm flat blade torque screwdriver for internal protective earth terminal

• Adjustable spanner to fit cable gland

• Installation of the vibration switch shall only be carried out by qualified personnel

• Remove vibration switch from carton

• Vibration switch is factory set to 3

g

, unless a preset switch has been ordered

• To reduce the risk of damaging internal components and wiring, installation and wiring must

be performed within a temperature range of -10°C to +50°C

• Do not allow moisture or other airborne contaminants inside the switch as they can cause

corrosion

• When closing the lid, ensure the seal is not lost or damaged.

• Explanation of Tamb*: To maintain T6 temperature classification the vibration switch

maximum surface temperature due to any combination of ambient temperature and heat

from attached machinery the operating current of the vibration switch (which can cause

internal heat generation) must be limited as shown in the graph and table below;

Summary of Contents for 3171 Ex

Page 1: ...and harmonics The switch responds by shutting off the machine if any components of vibration exceed the set value The switch operates as follows Mounted vertically on a vibrating machine a steel ball...

Page 2: ...the field and not wired Unless the switch is immediately wired using a suitable cable gland replace the Cable Entry Cap with Blanking Plug 0051 002 01 see accessories For Ex compliance ensure a minimu...

Page 3: ...ch is factory set to 3 g unless a preset switch has been ordered To reduce the risk of damaging internal components and wiring installation and wiring must be performed within a temperature range of 1...

Page 4: ...itch shall be firmly fixed in the vertical orientation shown in figure 1 to a vertical surface of the vibrating machine using M5 fixings suitably resistant to vibration Figure 1 Mechanical installatio...

Page 5: ...at failure of the strain relief will cause the Earth wire to be the last conductor interrupted To prevent water running down onto the vibration switch add a drip loop in any external cabling For ambie...

Page 6: ...ess multiple conductors have been joined in a suitable manner e g by a single insulated crimped bootlace ferrule Wiring to terminals shall be insulated for the appropriate voltage and this insulaton s...

Page 7: ...7 Figure 4a Wiring Configuration Switches are shown in their reset state x4 3mm hex 1Nm max Check lever moves freely up and down Figure 5 Figure 4b Typical Installation Circuit Diagram...

Page 8: ...N N Advance SET LEVEL SCREW steadily 1 2 turn Reset switch Reset Machine 5 Set up Sequence No adjustment is needed if the vibration switch has been ordered preset for your application Otherwise the vi...

Page 9: ...referring to the calibration curve in figure 6 and counting the number of turns from the factory setting If the factory setting is lost it can be approximated as 11 5 turns from flush Figure 6 Vibrat...

Page 10: ...s not required except for periodic external visual inspection of the following Confirm lid screws and vibration switch M5 fixings to machine are tight Confirm cable gland is tight to the enclosure and...

Page 11: ...Picture 1000 026 LID ASSEMBLY TYPE MR G003 GLAND M20 TRS C I P S171 SEAL 400 024449041 1000 027 4MM HEX DRIVER LONG 0051 002 01 BLANKING PLUG IP66 67 23640 083 ADAPTOR 20mm MALE 23640 085 CABLE GLAND...

Reviews: