5-14
C
OMMISSIONING
THE
ALINTE
4
PAGE
S
YSTEM
Enter the 96 resolution values into the 96, 100, 144, 2400 and 3600
BCF positions in the Final Values Table.
5.3.3 Calculating Values for 48 Resolution Test
Strips
Figure 5.7 48 resolution test strips
NOTE:
Figure 5.7 on page 5-14
shows the Focus 48H test strips.
This set consists of 11 strips each 12 mm wide. The focus set-
ting for each strip is shown here for illustrative purposes only
and will not appear on the exposed plate.
1.
Measure the density at the
top
of each strip to find the strip with the
lowest density.
Select the focus setting for the lowest density test strip.
NOTE: The start value is 2500 and the step value is 200.
2.
Measure the density
mid-point
down each of the thirteen strips to
find the strip with the lowest density.
Select the focal setting for the lowest density strip.
3.
Measure the density at the
bottom
of each strip to find the strip with
the lowest density
Select the focus setting for the lightest strip.
The three recorded values should all be within
400
of each other, if
not, check the plate again to confirm your values.
TOP
MID-POINT
BOTTOM
Summary of Contents for alinte4page
Page 1: ......
Page 12: ...PRELIMINARIES...
Page 29: ...ALINTE4PAGE INSTALLATION GUIDE 2 7 Figure 2 5 Autofeeder elevator warning label...
Page 40: ...2 18 SAFETY ON THE ALINTE4PAGE Figure 2 13 Location of interlock covers alinte4page SAL 2 1...
Page 48: ...2 26 SAFETY ON THE ALINTE4PAGE...
Page 56: ...3 8 UNPACKING AND HANDLING...
Page 98: ...4 42 INSTALLING ALINTE4PAGE EQUIPMENT AND SOFTWARE Figure 4 32 Removing transit fixing view 2...