Manual ResistTel IP2 / IP152
Page 53
ExResistTel IP2 / IP154
2.4.2.4.1.3
Version with Switch LAN Module with two LAN
Connections with Cable Screw Caps
The telephone has in this version two internal LAN-connections with a cable screw
cap. For the connection the LAN cable must be pulled through the cable screw cap.
Inside the phone the female LAN connection from Tycoelectronics (AMP) has to be
pressed on the cable (Refer to chapter 2.3 beginning on page 22). A female LAN
cable connector belongs to the as-delivered condition. With the inside the phone
existing little LAN connection cable, the LAN can be connected with the phone. For
the wiring of an Ethernet cable see chapter 2.4.2.1 on page 48.
The LAN1 delivery can be available with PoE (Power over Ethernet). Alternatively the
phone can be supplied with power external.
The LAN2 delivery doesn’t support PoE. Also it can’t be used to connect a phone
directly, which should be powered with PoE.
All not used cable feed through have to be closed with sealing plugs.
2.4.2.4.1.4
Version with Switch LAN Module with two LAN
Connections with two Female Housing Connections
The phone has in this version two LAN-connections with a female LAN connection at
the housing. LAN-cable, used for plug into the telephone ResistTel IP2 / IP152, have
to be adapted with a connector from Phoenix contact (Refer to chapter Refer to
chapter 2.3 beginning on page 22), to preserve the IP66 degree of protection. A LAN
cable connector belongs to the as-delivered condition. For the wiring of an Ethernet
cable see chapter 2.4.2.1 on page 48.
The LAN-lead wire has to be connected to the connector in the front. Die LAN1 lead
wire can to be with PoE (Power over Ethernet). Alternatively the phone can be
supplied with power external.
The second LAN connector of the ResistTel IP2 / IP152 doesn’t support PoE. Also it
can’t be used to connect a phone directly, which should be powered with PoE.
If the second LAN connector of the ResistTel IP2 / IP152 will not be used, it has to
be closed with the at the phone available protection plug to preserve the degree of
protection IP66.
All not used cable feed through have to be closed with sealing plugs.
Summary of Contents for ExResistTel IP2/IP154
Page 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Page 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Page 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Page 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...