Page 12
Manual ExResistTel
IP2
2
Commissioning
For operation and commissioning, the application of standard IEEE 802.3 is
compulsory.
The ExResistTel IP2
telephone must be connected to a LAN (Local Area Network)
connection. The telephone can be powered with PoE (Power over Ethernet). In this
case the power supply must use the free cable pairs. Using the phantom power
supply is not possible and not allowed.
Alternatively the telephone connected with an external DC power supply
(19.2 V –
52.8 V, 12.95 W)
.
2.1
Mounting
The telephone must be installed on a plane surface in vertical operating position
only. Loosen the cover screws and detach the upper part of the telephone (1). If the
optional accessory headset is being employed, attach the bracket using two screws
to the rear panel of the lower part of the telephone. (With the accessories named
before, the bracket and screws are in the scope of delivery. With all accessories a
cable gland is delivered.) Put four screws, having a head diameter of 10 to 13 mm
into the holes (20) and attach the lower part of the telephone (3) to the wall or to a
holder.
Guide the telephone wire through the cable screw cap (4) and place it on the
terminals. Only wires having a sheath diameter of 5.5 to 13 mm should be used
because otherwise the IP66 housing protection standard is not guaranteed.
Prior to assembly, check cover seal for tightness. Using the plug connector (7), plug
the ribbon cable onto the pin contact strip (8) in the upper part of the housing.
Attach the upper part of the telephone and fasten it to the lower part of the
telephone with the four cover screws (2). Upon disassembly of optional accessories,
suited sealing plugs must be used to close the resulting openings.
In this telephone connected cords may have hazardous voltages.
To ensure that no water gets into the enclosure it is essential that no gaskets are
damaged during installation. The ingress of water can cause accessible parts of the
telephone to become live.
For mounting of the cable screw caps only dedicated toys are allowed.
The cable screw caps are useful for fixed mounted cables only.
Summary of Contents for ExResistTel IP2
Page 1: ...Explosion proof VoIP telephone Operating instructions FHF BA 9711 03 13...
Page 23: ...Manual ExResistTel IP2 Page 23...
Page 24: ...Page 24 Manual ExResistTel IP2...
Page 26: ...Page 26 Manual ExResistTel IP2 4 3 Declaration of Conformity ExResistTel IP2...
Page 27: ...Manual ExResistTel IP2 Page 27...