65
www.fhiaba.com · sales@fhiaba.com · Info Line 800-344222
EN
10.2 Cleaning of the ventilation grille,
filter and condenser.
The unit requires, for a correct operation, the
cleaning of the ventilation grille, filter and
condenser.
The recurring clenaning every 6 months is remin-
ded by an acoustic and optical signal on the dispaly.
It is possible to disable the warning signal and see
the time left before the next cleaning has to be done.
Behind the frontal ventilation grille (situated in the
upper part of the units in the series StandPlus,
Country e X-Pro, in the lower part of the units in the
series Integrated, Brilliance e Classic) there is the
condenser. See page 7 paragraph 3.2.
To clean it use a vacuum cleaner with a soft
brush attachment at maximum power, swee-
ping it along the vent slits. In case of a significant
dust build up, the ventilation grille can be remo-
ved to allow a more accurate cleaning of the filter.
On the mantenience settings, after the
installation of the unit and after it has been turned
on, you can set the condenser cleaning warning.
In the case the warning sign will be enable, there
will be an acoustic signal every 6 months, that
tells that is time to clean the condenser.
After cleaning it, touch the reset icon in order to
reactivate the warning signal in 6 months.
In the case you do not want the warning cleaning
signal of the condenser anymore, touch the off icon.
For knowing how to use the mainteniance display,
see page 23.
See instruction point 11.2 throught the video tutorial
available on the Fhiaba’s website.
www.fhiaba.com/en/support/
video
“Bottom Condenser Cleaning”.
Upper condenser.
For cleaning the condenser in the models X-Pro,
StandPlus e Country follow the instructions:
>
Switch off the appliance by pressing the Unit
button on the main control panel for approx 3
seconds.
>
Wait approx 30 minutes, until the finned condens-
er cools down to room temperature.
>
Lifting up the removable grille.
>
Clean it thoroughly from any dust build up as
shown in the picture, taking care not to damage it.
Restart the unit pressing for 3 seconds on the on
button .
Warning
The edges of the condenser are sharp,
therefore use adequate protection for
the hands and arms when cleaning the
condenser.
Maintenance
Summary of Contents for AS5991TWT3
Page 1: ...Cantina vini Manuale utente Wine cellars User manual ...
Page 2: ...2 www fhiaba com sales fhiaba com Info Line 800 344222 ...
Page 35: ...35 www fhiaba com sales fhiaba com Info Line 800 344222 IT ...
Page 36: ...36 www fhiaba com sales fhiaba com Info Line 800 344222 ...
Page 69: ...69 www fhiaba com sales fhiaba com Info Line 800 344222 EN ...
Page 70: ...70 www fhiaba com sales fhiaba com Info Line 800 344222 ...
Page 71: ...71 www fhiaba com sales fhiaba com Info Line 800 344222 ...