background image

Hollow shaft display

EP25L

Date: 13/01/16

file: EP25L_ing.doc

pag 6/6

Technical features

Hollow shaft diameter

25mm H7

Max. rotation speed

1000 RPM

Resolution

4000 impulses/revolution

Range

-999999; 999999

Display

LCD high readability with 10mm-high-digits

Keyboard

3 digits for programming and functions activation

Available functions

reset/preset, absolute/incremental quota, conversion
mm/inches, visualization in degrees, 3 distinct origins for tool
changing,  tool wear adjustment

Power supply

2 alkaline batteries 1,5V type AA

Weight

370g

Protection degree

IP54

Working temperature

0-50°C

Relative humidity

35-85%

Electromagnetic compatibility

2014/30/EU

RoHS

2011/65/EU

Manufacturer

All communications to the manufacturer should be addressed to:
FIAMA s.r.l., Via G. Di Vittorio, 5/A - 43016 San Pancrazio (Parma) - Italy
Tel. (+39) 0521.672.341 - Fax. (+39) 0521.672.537 – e-mail: info@fiama.it - www.fiama.it

FIAMA srl is not responsible for any damage to persons or things caused by tampering and wrong
use and in any case that are not consistent with the features of the instrument.

Summary of Contents for EP25L

Page 1: ...Hollow shaft display EP25L Date 13 01 16 file EP25L_ing doc pag 1 6 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP25L ...

Page 2: ...to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth...

Page 3: ...arings The power supply is internal with 2 batteries type AA of 1 5V one year life The run down of battery is indicated with occasional blinking 1 month before the complete flat the indication remains on the battery has to be changed in very easy way and without loosing quota while the shaft is standing Programming To step into the parameter programming press key and on the display appears now pre...

Page 4: ...small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of shaft for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin 1 in the...

Page 5: ... to take off the front cover prising on the two hollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switche...

Page 6: ...t origins for tool changing tool wear adjustment Power supply 2 alkaline batteries 1 5V type AA Weight 370g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 341 ...