Display panel mount for magnetic band

F8P

Data: 13/01/16

F8P_ing.doc

pag 5/9

In practice 

3U6

3U6

3U6

3U6

,

3U6

3U6

3U6

3U6

, and 

3U6

3U6

3U6

3U6

 are the nominal values associated to the three different tools

which are used.
As a special case, if 

3U6

3U6

3U6

3U6

 is set to zero, 

3U6

3U6

3U6

3U6

 and 

3U6

3U6

3U6

3U6

 are the values to display in origin 1 and in

origin 2 respectively.

ABS

/

REL

 function:

 

Enables passing from an absolute to relative value; after pressing  , the

displayed value is temporarily set to zero to measure a relative motion of the transducer. On the
display the 

REL

 icon indicates that the current display is relative to the reference point that has just

been created. Pressing again   causes the absolute value to be displayed and the 

ABS

 icon will

appear.

mm/inch conversion:

 Pressing 

 converts the measurement from millimeters to inches and

back. When in inch mode, the 

INCH

 icon will appear and the displayed value will have an additional

decimal place. When the parameter 

QG(&

QG(&

QG(&

QG(&

=4 the mm/inch conversion is not available.

Offset: 

This parameter is added to or subtracted from the displayed value to correct it in case, for

example, of a tool change or to compensate tool wear. After setting a positive offset value, the
displayed value will be the measured value plus the offset value. After setting a negative offset
value, the displayed value will be the measured value minus the offset value.

Fast Offset

: After pressing 

ENTER

/

RESET

,

 

2))6W

2))6W

2))6W

2))6W

 appears and by pressing two times 

ENTER

/

RESET

it is possible to set directly the value to be displayed (use buttons   

 and confirm with

ENTER

/

RESET

). This function is useful if it is necessary to correct often the displayed value.

%.

%.

%.

%.

Count direction

Set out the count direction of the display, range allowed 0 or 1.

Adjustment of displayed value

After the installation of instrument on the machine and setting of all parameters, in order to visualize
on the display the correct value it is necessary to carry out the reset or preset.
Position the shaft in a point in which the correct measure that has to be visualized is known exactly
(for example the stroke end point) or measure the position in that point of the shaft. Program
parameter 

W$6W,

W$6W,

W$6W,

W$6W,

 with value 3 in the first digit on the right and exit programming.

Now press 

ENTER

/

RESET

 and 

3U6W

3U6W

3U6W

3U6W

will appear, press again 2 times 

ENTER

/

RESET

 and set the correct

value to display, then confirm with 

ENTER

/

RESET

The display will now show the desired value.

If the required value is zero, instead of the preset function it is possible to use the reset function by
setting 1 in the first digit on the right in the 

W$6W,

W$6W,

W$6W,

W$6W,

parameter so that pressing 

ENTER

/

RESET

 will bring

the displayed value to zero.
Now that the instrument is adjusted, it is necessary to insert the desired 

W$6W,

W$6W,

W$6W,

W$6W,

parameter to avoid

accidental reset/preset of the displayed value.

Battery replacement

The instrument is supplied with a ½AA 3,6V lithium battery, which assures a typical functioning of
approximately 4 years.
When the battery runs down, an icon appears on the display.
The instrument is protected against inversion of polarity and wrong insertion, and in this case will
not switch on.
Removing the battery from the instrument switches it off after a few seconds: at this point do not
move the sensor to avoid losing the correct displayed value. As soon as the battery is fitted, the
instrument switches on with the same value on the display which was present at the moment when
it was switched off. If the sensor has not be moved, the displayed value will be correct. In case the
sensor moved when the instrument was off, to re-establish the correct measure it is necessary to
repeat the adjustment process.

Summary of Contents for F8P

Page 1: ...Display panel mount for magnetic band F8P Data 13 01 16 F8P_ing doc pag 1 9 USER S MANUAL AND MAINTENANCE DISPLAY PANEL MOUNT FOR MAGNETIC BAND WITH BATTERY POWER SUPPLY TYPE F8P ...

Page 2: ...ere below are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic c...

Page 3: ...hich can be activated by pressing the corresponding button The electronics are seated in a smart and strong black anodized aluminum case The display can be fixed quickly and easily using the two holes on the housing The unit is powered by a AA 3 6V battery which lasts approximately 4 years and when the battery is almost exhausted an icon will appear to advise the operator to substitute it This doe...

Page 4: ...t or preset it is necessary to keep ENTER RESET pressed for approximately 3 s Reset reset function of the displayed value after pressing ENTER RESET the displayed value is set to zero Preset preset function of the displayed value after pressing ENTER RESET the displayed value becomes equal to the value in the 3U6W 3U6W 3U6W 3U6W parameter which can be set immediately after W 6W W 6W W 6W W 6W when...

Page 5: ... 0 or 1 Adjustment of displayed value After the installation of instrument on the machine and setting of all parameters in order to visualize on the display the correct value it is necessary to carry out the reset or preset Position the shaft in a point in which the correct measure that has to be visualized is known exactly for example the stroke end point or measure the position in that point of ...

Page 6: ...gnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles of 5 mm pitch carried by a ferromagnetic steel strip Mechanical protection of the plastic ferrite strip is supplied by a non magnetic steel strip with thickness 0 2mm The magnetic strip is assembled by sticking it with a bi adhesive tape The surface has to be smooth clean and dry is advisable to clean it ...

Page 7: ...sor has be mounted according to the following draw and keeping the indicated tolerances For the optimal system functioning its is necessary that the distance between the sensor and the magnetic band is not over 1mm of the useful stroke Mounting of magnetic ring only for version F8P E AM 3 3 3 M A X 1 ...

Page 8: ...Display panel mount for magnetic band F8P Data 13 01 16 F8P_ing doc pag 8 9 Mounting of sensor SM12 only for version F7P E SM12 Overall dimension ...

Page 9: ...on degree IP54 display IP67 sensor Sensor cable length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Display and sensor house alluminium black Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via...

Reviews: