background image

Display panel mount for magnetic band

F8P

Data: 13/01/16

F8P_ing.doc

pag 6/9

Display icons

1.

Indicator of flat battery: begins to blink when the level of loading goes under a certain value
and when it   keeps switched on its necessary to change the batteries within 1 month.

2.

Indicator of absolute quota

3.

Indicator of relative quota

4

. Indicator of mm

5.

Indicator of inches

6.

Indicator of degrees

7.

Indicator of positive Offset: indicates that the measure is corrected by a positive offset

8.

Indicator of negative Offset: indicates that the measure is corrected by a negative offset

9.

Indicator of values changing: it blinks during the programming phase

10.

Indicator of origins: indicates that the origin changing mode is opened

11.

Indicator for origin 1

12.

Indicator for origin 2

Error message

RX(U

RX(U

RX(U

RX(U

: the current displayed value passed the maximum value that can be visualized (possible

range: from –999999 to 999999).

Magnetic strip mounting

The magnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles
of 5 mm pitch, carried by a ferromagnetic steel strip. Mechanical protection of the plastic ferrite
strip is supplied by a non magnetic steel strip with thickness 0,2mm.

The magnetic strip is assembled by sticking it with a bi-adhesive tape. The surface has to be
smooth, clean and dry: is advisable to clean it with a degreasing product (isopropyl alcohol, ethyl
alcohol, solvents, etc). The magnetic strip has to be stuck holding the plastic ferrite side in the
direction of the sensor, which means the steel side leaned on the stand surface.  Fixed the
magnetic strip, to keep off damages due to abrasions or grazes of the plastic ferrite strip, is
advisable the appliance (always bi-adhesive) of the non magnetic protection strip.  The optimal
ambient temperature for stick the bi-adhesive tape is over 10°C.  The maximum adherence of the
tape works out after 48 hours (about) of the application and is kept between –10 and 80°C.

1,7

non magnetic steel strip

(mechanical protection)

plastic ferrite strip

steel strip 
(plastic ferrite support)

10

sensor side

1

2

7 8

10

3

9
6
5
4

11

12

Summary of Contents for F8P

Page 1: ...Display panel mount for magnetic band F8P Data 13 01 16 F8P_ing doc pag 1 9 USER S MANUAL AND MAINTENANCE DISPLAY PANEL MOUNT FOR MAGNETIC BAND WITH BATTERY POWER SUPPLY TYPE F8P ...

Page 2: ...ere below are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic c...

Page 3: ...hich can be activated by pressing the corresponding button The electronics are seated in a smart and strong black anodized aluminum case The display can be fixed quickly and easily using the two holes on the housing The unit is powered by a AA 3 6V battery which lasts approximately 4 years and when the battery is almost exhausted an icon will appear to advise the operator to substitute it This doe...

Page 4: ...t or preset it is necessary to keep ENTER RESET pressed for approximately 3 s Reset reset function of the displayed value after pressing ENTER RESET the displayed value is set to zero Preset preset function of the displayed value after pressing ENTER RESET the displayed value becomes equal to the value in the 3U6W 3U6W 3U6W 3U6W parameter which can be set immediately after W 6W W 6W W 6W W 6W when...

Page 5: ... 0 or 1 Adjustment of displayed value After the installation of instrument on the machine and setting of all parameters in order to visualize on the display the correct value it is necessary to carry out the reset or preset Position the shaft in a point in which the correct measure that has to be visualized is known exactly for example the stroke end point or measure the position in that point of ...

Page 6: ...gnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles of 5 mm pitch carried by a ferromagnetic steel strip Mechanical protection of the plastic ferrite strip is supplied by a non magnetic steel strip with thickness 0 2mm The magnetic strip is assembled by sticking it with a bi adhesive tape The surface has to be smooth clean and dry is advisable to clean it ...

Page 7: ...sor has be mounted according to the following draw and keeping the indicated tolerances For the optimal system functioning its is necessary that the distance between the sensor and the magnetic band is not over 1mm of the useful stroke Mounting of magnetic ring only for version F8P E AM 3 3 3 M A X 1 ...

Page 8: ...Display panel mount for magnetic band F8P Data 13 01 16 F8P_ing doc pag 8 9 Mounting of sensor SM12 only for version F7P E SM12 Overall dimension ...

Page 9: ...on degree IP54 display IP67 sensor Sensor cable length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Display and sensor house alluminium black Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via...