Manual purpose

This manual has been designed by the manufacturer to provide the necessary information regarding the
instrument MAT2 to those who are authorized to carry out safely its installation, maintenance, dismantling
and disposal. All the necessary information for the buyers and planners can be found in the Sales catalogue.
Other than adopting good technical construction methods, the information should be read carefully and
strictly applied. Inobservance of this information could cause risks for the health and safety of people and
economical damage. This information, provided by the Manufacturer in the original language(Italian) is also
available in other languages to satisfy legislative and/or commercial needs. This manual must be kept in good
conditions by a responsible person in an ideal place so that it is always available for consultation. In case this
manual is lost or deteriorates, a replacement should be requested directly from the manufacturer quoting the
manual’s code. This manual reflects the state of skill of the instrument at the time of input on the market:
however the manufacturer reserves the right to make changes, add or improve the manual without giving any
reason to hold the present manual inadequate.

Identification of the equipment

The identification plate represented is applied on the instrument.
To find out the identification code of the instrument, consult the sales catalogue.

Environmental conditions

Temperature setting: min. 0°C, max. + 50°C.
It is forbidden to use the instrument other than its specific use and in potentially explosive conditions or where
anti- explosive elements are used.

Storage

Here below are some references to be followed for the storage of the instrument.
Avoid environments with excessive humidity and those exposed to bad weather (avoid open areas). Avoid
putting the instrument directly on the ground. Store the instrument in its original packing.

Conformity declaration and EC marking

The instrument answers to the following Communitarian Directives:
2014/30 UE Elettromagnetic Compatibility
2011/65 Rohs

Maintenance

The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth dampen
with ethylic alcohol or water. Do not use hydrocarbon solvents (petrol, diluents, etc.): the using of these
products could affect the proper functioning of the instrument.
Reparations should be done only and exclusively at the FIAMA technical assistance centre.

Calibrations and tests

It is advisable to verify the transducer calibration periodically, once every working year.

Assistance request procedure

For any kind of technical assistance request, contact the sales department of the Manufacturer directly
indicating the information given on the identification plate, the number of hours used and the type of defect.

Manufacturer’s responsibility

The manufacturer declines any responsibility in case of :
• Using the instrument contrary to the national safety and accident-prevention laws.
• Wrong installation, inobservance or wrong procedures of the instructions provided in the present manual.
• Defective electrical power supply.
• Modifications or tampering.
• Operations carried out by untrained or unqualified staff.
The safety of the instrument also depends on the strict observance of the procedures indicated in the
manual: always operate the instrument in its functioning capacity and carry out a careful routine maintenance.
• All phases of inspection and maintenance should be done by qualified staff.
• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current legislation
regarding the safety laws.

Summary of Contents for MAT2

Page 1: ...MAT2_ Data 15 01 18 file MAT2_ing doc Rev 2 pag 1 7 USER S MANUAL AND MAINTENANCE ABSOLUTE TRANSDUCER MAT2_ ABSOLUTE MAGNETIC BAND PA50 10 ...

Page 2: ...essive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 UE Elettromagnetic Compatibility 2011 65 Rohs Maintenance The instrument does not needs a particular maintenance except cleani...

Page 3: ...ice a sensor sensible to magnetic fields an electronic signals conversion circuit and an output stage The most importan feature is that this sensor always keeps the quota it means that is possible to move the sensor also without power supply and without loosing the quota There are available two inputs to define the zero setting and the direction The data exchanging is made through protocol SSI wit...

Page 4: ...netic sensor is necessary to observe the quotas mounting on the following draws pay attention that the distance between the sensor and the magnetic band doesn t exceed 0 8 mm Alignement tolerance magnetic band transducer A color led indicator shows the following state 1 green transducer power on ok 2 red error condition ...

Page 5: ...band has to be sticked holding the plastic ferrite side in the direction of the sensor which means the steel side leaned on the stand surface Fixed the magnetic band to keep off damages due to abrasions or grazes of the plasic ferrite strip is advisable the appliance always biadhesive of the non magnetic protection streep The optimal ambient temperature for stick the biadhesive tape is over 10 C T...

Page 6: ...ings are the same If in one of the two cycles the value is corrupted by noise the two values will be different and the reading must be repeated The data is a 24 or 25 bit right aligned Binary or Gray coded Zero point setting After the transducer has been positioned on the magnetic band it is necessary to set the value to zero otherwise the minimum value can be any value within the admissible range...

Page 7: ...ion Cable Ø6 6 PUR standard lenght 2 5 10m Output SSI RS422 Data output 24 bit Gray binary code optional parity 25 bit Gray binary code optional parity Clock SSI 32KHz 1 5MHz Protection degree IP66 Case Alluminium Working temperature 0 50 C Electromagnetic compatibility 2014 30 UE PA50 10 MAGNETIC BAND Length max 40 955 m Width 10 mm Thickness 1 7 mm Bending radius 75mm Linear thermal expansion co...

Reviews: