MTP_
Data: 13/01/16
file: MTP_ing.doc
pag 5/5
Connection scheme
Brown
+10÷25VDC / 5VDC
Yellow
signal A
Orange
signal /A
White
signal B
Geen
GND
Shield
internally not connecetd
Purple
signal /B
LINE DRIVER TTL
OUTPUT
(type: MTP2, MTP3, MTP4)
Gray
signal Z
Black
signal /Z
Brown
+10÷25 VDC
Yellow
signal A
White
signal B
Gray
signal Z
PUSH-PULL
OUTPUT
(type: MTP1)
Geen
GND
Shield
internally not connecetd
Output signals
The measure transducer turns the shifting compared to the magnetic band in digital signals with two squaring
channels (A, B) very similar to the signals produced by incremental encoders or optical lines. Every 5 mm you
have a reference impulse (Z) which can be used as the zero-setting signal of the quota. Pay attention: if the
reference signal Z isn’t used it has to be isolate electrically of the other signals and of the power supply.
0,04 mm
signal A
signal B
signal Z
0,02 mm periodic every 5 mm
RESOLUTION
:
•
0,04mm x1 count
•
0,02mm x2 count
•
0,01mm x4 count