background image

21689_r03 

 

11/13

 

WARNING! 

The  GSM  modem  must  be  equipped  with  a  SIM  card 

active  and  able  to  send  and  receive  SMS;  before 

inserting the SIM in the modem, you must disable any 

PIN code request,  

You  can  only  send  SMS  from  numbers  with 

international prefix Italian ("+39"). 

At this date, the GSM function is only for Italy. 

On  request,  the  GSM  function  can  be  implemented  to 

operate in other states. 

 

 

TECHNICAL DATA SERIAL COMMUNICATION 

protocol RS-232 

baud-rate 2400 bit/s 

use  of  AT  commands  according  to  standard  GSM 

07.07 and 07.05 

use of 5 conductors (TX, RX, GND, DSR, CTS) 

 

 

 

CRONO 

(DTE)

 

MODEM 

(DCE)

 

D-SUB 15 

SIGNAL 

CON. 8 POLES 

Tiye Molex 

90327-0308 

(J2 on pcb) 

CONN. DB9 

CONN. 15 

POLES 

TX 

(CT103)

 

RX 

(CT104)

 

GND 

DSR 

CTS 

11 

 

Table  1:

    Correspondence  between  the  connector  pins  of 

the serial cable. 

 

 

Figura 3

 Position connector J2 on C.S. for connection with 

a GSM modem 

 

 

Displaying modem status 

In the line on  central text of LCD display you can check the 

status of the modem. 

Particularly in the initial phase, if the modem is detected, if 

the SIM card is active and the GSM network is present, the 

screen will "automatically" appears as follows: 

 

 

 

in  addition  to  the  usual  information,  there  is  shown  the 

GSM  signal  level  (0  to  5  "levels")  and  the  name  of  the 

operator. 

 

More  information  on  communication  with  the  modem  can 

be  viewed  by  entering  the  submenu  "RS232  Monitor" 

located in "Menu parameters". 

In the first page shows the status of the modem, the serial 

communication (right), the name of the GSM operator and 

the level of the signal. 

 

 

 

Pushing  the  "Buffer"  you  can  view  the  data  exchanged 

between  the  chronothermostat  and  modem,  for  diagnostic 

operations. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for OT11

Page 1: ...d the control board of the boiler takes place by means of a two wire cable the data are exchanged with the communication protocol compatible OpenTherm v3 0 Smart Power Mode Medium Power GENERAL TECHNICAL DATA FIAMMA design graphic LCD 128x64 pixel backlight timer 20 seconds LED for diagnostics signaling 7 variable function keys weekly programming 4 temperature levels T0 T1 T2 T3 resolution 0 5 C t...

Page 2: ...t boiler lockout LED with color yellow intermittent anomaly LED with color green continuous the chronothermostat is resuming work after a power failure The most frequently used functions by the user are available in the main menu It is possible to quickly browse through the pages to set for example environment temperature or the domestic hot water temperature The first time or after a reset of the...

Page 3: ...er is in stand by and has no problem Under the indication of the ambient temperature may be present in addition a line of text that provides information to the user in special cases such as the presence of error or the status of additional functions such as management of a system of solar panels integrated with the boiler and managed by the thermoregulation board Here there are the messages that m...

Page 4: ...t thermoregulation The management of the cronothermostat by the user is much simplified The functions are not distinct between the functions relating to boiler and functions relating to thermoregulation Pushing again button you switch to another option This option allows you to turn off the system temperature control environment and demand hot water operation are disabled The first level menu is c...

Page 5: ...u has a frame fixed The options previously seen remain displayed for 20 seconds then the display returns to the main screen which depends on the chosen operation mode manual automatic estate vacation off In this option however if the user does not push ESC or not push or the crhonothermostat continues to show the control panel with its solar collector and accumulation temperatures and pump status ...

Page 6: ... lowest temperature with T0 the chronothermostat meets the following constraint T0 T1 T2 T3 and automatically resizes the temperatures Choosing the option Day program you enter in the following screen At the top of the screen you select the day and at the bottom of the screen displays the day program Pressing the and buttons you can select the day For example suppose you want to program the day Mo...

Page 7: ...emperature It is a regulation that requires a specific knowledge of the heating system installed and is reserved therefore for advanced users make changes without knowledge of the techniques of temperature control is not recommended The chronothermostat allows you to choose among four methods of temperature control environment Proporzional On Off Outside temperature compensation Outside temperatur...

Page 8: ...circuit heating according to the formula Ti Tap Te hc Tap when Ti circuit heating setpoint Tap room temperature setpoint Te external temperature measured hc dispersion coefficient In this formula correspond to the curves shown in Fig 2 Outside temperature compensation with mix This method of temperature control is the same climatic compensation just described with a correction dependent on the amb...

Page 9: ... status flags CH OT S P Control setpoint circuit heating C Solar cfg Solar configuration Solar sta Solar status Storage Solar storage temperature C Collector Solar collector temperature C The values displayed are updated regularly by the chrothermostat every few seconds To force loading you can press the middle button transparent and get an instant update Pushing ESC instead to return to the main ...

Page 10: ...een chronothermostat and thermoregulation board master side In particular next to the data the following symbols appear correct data exchange T timeout RX error R RX error generic error unknown P parity error E syntax error Through the Restart command is possible to reconfigure the chronothermostat after interventions hardware software occurred without disconnecting the power adapter on thermoregu...

Page 11: ...6 8 11 Table 1 Correspondence between the connector pins of the serial cable Figura 3 Position connector J2 on C S for connection with a GSM modem Displaying modem status In the line on central text of LCD display you can check the status of the modem Particularly in the initial phase if the modem is detected if the SIM card is active and the GSM network is present the screen will automatically ap...

Page 12: ...ONNECTION TO THE BOILER INSTALLATION INSTRUCTIONS Respect National and European standards EN 60335 1 pr EN50165 regarding electrical safety Before turning on check the cables incorrect wiring may damage the devices and compromise safety Connect and disconnect the control system only in the absence of voltage Avoid exposing the system to dripping water INSTALLING THE CHROTHERMOSTAT ON THE WALL Firs...

Page 13: ... 370049 Villa Bartolomea VR ITALY Tel 39 0442 659028 Fax 39 0442 659045 http www fiammagiro com E mail info fiammagiro it 22 05 2017 Subject to amendments without notice 140 0 90 0 1 2 30 8 Figure 6 external dimension 9 50 5 00 9 00 2 20 5 00 10 40 9 50 18 25 17 15 ø 3 80 Figure 5 fixing holes of the base back view NOTE FIAMMA OT11 is available in white shown on page 1 or black as the image ...

Reviews: