MANAGEMENT SYSTEM 

PARAMETERS MENU 

 

The  submenu  "PARAMETERS  MENU"  allows  you  to 

remotely manage the boiler.

 

Pushing the 

 and 

 buttons, you scroll through the various 

items. 

 

First page: 

 

 

Second page: 

 

 

The first item  "Read" allows you to read the parameters of 

the system remotely. 

Pushing the OK button is activated the first page of reading 

parameters. 

 

 

 

The  parameters  are  active  if  the  thermoregulation  board 

manages the corresponding parameters. 

The parameters are specific of OpenTherm protocol and to 

understand the meaning is necessary to know the protocol 

OpenTherm. 

The  parameters  available,  in  different  pages,  are  the 

following: 

 
CH Temp. 

Circuit heating temperature (°C) 

Ret. Temp. 

Return water temperature (°C) 

DHW Temp. 

DHW temperature (°C) 

Out Temp. 

Outside temperature (°C) 

Exhaust T. 

Boiler exhaust temperature (°C) 

Mod. level 

Relative modulation level (%) 

CH Press. 

Water pressure in CH circuit (bar) 

DHW Flow 

Water flow rate in DHW circuit. (l/m) 

Fault flgs 

Fault flags 

Fault code 

OEM fault code 

TSP max 

Number of transparent-slave-parameters 

FHB max 

Max. dimension fault-history buffer 

Slave cfg. 

Slave configuration flags 

Slave sta. 

Slave status flags 

Master sta. 

Master status flags 

CH OT S.P. 

Control setpoint circuit heating (°C) 

Solar cfg. 

Solar configuration 

Solar sta. 

Solar status 

Storage   

Solar storage temperature (°C) 

Collector 

Solar collector temperature (°C) 

 

 

The  values  displayed  are  updated  regularly  by  the 

chrothermostat every few seconds. 

To  force  loading  you  can  press  the  middle  button 

transparent and get an instant update 

Pushing ESC instead to return to the main menu. 

 

The  second  item  on  the  "PARAMETERS  MENU"  allows 

you to send commands to the boiler. 

 

 

 

As shown in screen above, pushing the "Water filling" you 

can  load  the  hydraulic  system,  monitoring  the  pressure,  if 

the thermoregulation board manage it.  

In case of lockout of the boiler, in addition, you can send a 

request  for  remote  reset,  choosing  the  "Reset"  and  press 

ENTER. 

The remote reset is a safety function, the actual reset of the 

boiler is subject to the control of the safety logic board. 

You  can  also  unlock  the  boiler  from  the  main  screen 

(automatic  mode,  manual  mode,  etc..),  Pressing  the 

transparent button. 

 

The  third  item  concerns  of  the  transparent  parameters 

(TSP). 

This  function  depends  on  the  board  connected  to  the 

chrothermostat,  therefore,  please  refer  to  the  board's 

documentation for detailed description and the use of these 

parameters.  The  number  of  TSP  depends  of  the 

thermoregulation  board,  the  chronothermostat  supports  a 

maximum of 255 TSP (idx 001 to 255). 

Summary of Contents for OT11

Page 1: ...d the control board of the boiler takes place by means of a two wire cable the data are exchanged with the communication protocol compatible OpenTherm v3 0 Smart Power Mode Medium Power GENERAL TECHNICAL DATA FIAMMA design graphic LCD 128x64 pixel backlight timer 20 seconds LED for diagnostics signaling 7 variable function keys weekly programming 4 temperature levels T0 T1 T2 T3 resolution 0 5 C t...

Page 2: ...t boiler lockout LED with color yellow intermittent anomaly LED with color green continuous the chronothermostat is resuming work after a power failure The most frequently used functions by the user are available in the main menu It is possible to quickly browse through the pages to set for example environment temperature or the domestic hot water temperature The first time or after a reset of the...

Page 3: ...er is in stand by and has no problem Under the indication of the ambient temperature may be present in addition a line of text that provides information to the user in special cases such as the presence of error or the status of additional functions such as management of a system of solar panels integrated with the boiler and managed by the thermoregulation board Here there are the messages that m...

Page 4: ...t thermoregulation The management of the cronothermostat by the user is much simplified The functions are not distinct between the functions relating to boiler and functions relating to thermoregulation Pushing again button you switch to another option This option allows you to turn off the system temperature control environment and demand hot water operation are disabled The first level menu is c...

Page 5: ...u has a frame fixed The options previously seen remain displayed for 20 seconds then the display returns to the main screen which depends on the chosen operation mode manual automatic estate vacation off In this option however if the user does not push ESC or not push or the crhonothermostat continues to show the control panel with its solar collector and accumulation temperatures and pump status ...

Page 6: ... lowest temperature with T0 the chronothermostat meets the following constraint T0 T1 T2 T3 and automatically resizes the temperatures Choosing the option Day program you enter in the following screen At the top of the screen you select the day and at the bottom of the screen displays the day program Pressing the and buttons you can select the day For example suppose you want to program the day Mo...

Page 7: ...emperature It is a regulation that requires a specific knowledge of the heating system installed and is reserved therefore for advanced users make changes without knowledge of the techniques of temperature control is not recommended The chronothermostat allows you to choose among four methods of temperature control environment Proporzional On Off Outside temperature compensation Outside temperatur...

Page 8: ...circuit heating according to the formula Ti Tap Te hc Tap when Ti circuit heating setpoint Tap room temperature setpoint Te external temperature measured hc dispersion coefficient In this formula correspond to the curves shown in Fig 2 Outside temperature compensation with mix This method of temperature control is the same climatic compensation just described with a correction dependent on the amb...

Page 9: ... status flags CH OT S P Control setpoint circuit heating C Solar cfg Solar configuration Solar sta Solar status Storage Solar storage temperature C Collector Solar collector temperature C The values displayed are updated regularly by the chrothermostat every few seconds To force loading you can press the middle button transparent and get an instant update Pushing ESC instead to return to the main ...

Page 10: ...een chronothermostat and thermoregulation board master side In particular next to the data the following symbols appear correct data exchange T timeout RX error R RX error generic error unknown P parity error E syntax error Through the Restart command is possible to reconfigure the chronothermostat after interventions hardware software occurred without disconnecting the power adapter on thermoregu...

Page 11: ...6 8 11 Table 1 Correspondence between the connector pins of the serial cable Figura 3 Position connector J2 on C S for connection with a GSM modem Displaying modem status In the line on central text of LCD display you can check the status of the modem Particularly in the initial phase if the modem is detected if the SIM card is active and the GSM network is present the screen will automatically ap...

Page 12: ...ONNECTION TO THE BOILER INSTALLATION INSTRUCTIONS Respect National and European standards EN 60335 1 pr EN50165 regarding electrical safety Before turning on check the cables incorrect wiring may damage the devices and compromise safety Connect and disconnect the control system only in the absence of voltage Avoid exposing the system to dripping water INSTALLING THE CHROTHERMOSTAT ON THE WALL Firs...

Page 13: ... 370049 Villa Bartolomea VR ITALY Tel 39 0442 659028 Fax 39 0442 659045 http www fiammagiro com E mail info fiammagiro it 22 05 2017 Subject to amendments without notice 140 0 90 0 1 2 30 8 Figure 6 external dimension 9 50 5 00 9 00 2 20 5 00 10 40 9 50 18 25 17 15 ø 3 80 Figure 5 fixing holes of the base back view NOTE FIAMMA OT11 is available in white shown on page 1 or black as the image ...

Reviews: