28
The last item, "
Set thermostat
", allows to choose whether to link the request of
switching on of the boiler in heating mode issued by the current daily program with the
status of the room thermostat on the board.
In particular, in the "
Set thermostat
" section, if the "
Enable
" option is
ON
, the
boiler on in heating mode request generated by the daily program will only be considered
by the board if the room thermostat on the boiler is closed. However, if the "
Enable
"
option is
OFF
, the boiler will be switched on in heating mode as requested by the daily
program, irrespective of the status of the room thermostat on the boiler.
INTERNAL POWER RESERVE
The display has an internal back-up power reserve that can counteract the absence of
power for a few hours, so that the user will not have to reset the current time. However, the
duration of the power reserve is variable depending on the humidity and the ambient
temperature, as well as the age of the electronic components. For the power reserve to be
fully operational, the device must have been correctly and continuously powered for at
least two hours.
STORING DATA IN THE MEMORY
If even the internal power reserve described in the above paragraph is exhausted, the
display still saves some settings and data in the memory: display settings, WiFi settings,
weekly program and fault log.
It is possible to restore all the settings to the default values using the "
Factory
reset
" submenu in the "
SETTING DISPLAY
” menu.
WARNING: Pressing the "Reset" key on the back of the display will not restore the
factory settings.
BACKLIGHTING AND LED
The brightness of the display switches to maximum when a key is pressed, and returns to
the minimum value set one minute after the last pressing of any keys. For energy
efficiency purposes, after one minute only the LED under the
◄
(SW3
) key remains on. In
case of fault or boiler lock, all the LEDs come on and the LED under the
◄
(SW3
) key
flashes. In case of boiler lock, the display shows "
Res.
". Use the
◄
(SW3
) key to
unlock the components that control the operation of the boiler.
Summary of Contents for Silver Touch Elektra Compact 12 kW N
Page 2: ......
Page 42: ...41 SPARE PARTS 4 Detail view Electric Box Detail view Body Heating Elements 23 25 29 22 22 ...